Toward the Design of a Positron Volume Imaging Camera

نویسنده

  • P. E. Kinahan
چکیده

Three different computing algorithms for performing positron emission image reconstruction have been compared using Monte Carlo phantom simulations. The work was motivated by the recent announcement of the commercial availability of a positron volume imaging camera, the Siemens-CTI 953 B/31[1] which has improved axial (slice) resolution and retractable interslice septa. The simulations demonstrate the importance of developing a complete three-dimensional reconstruction algorithm to deal with the increased gamma detection solid angle and the increased scatter fraction that result when the interslice septa are removed from a ring tomograph. We are developing such an algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET Radiopharmaceuticals

PET (positron emission tomography) is a powerful imaging technique that can provide quantitative information on the distribution of positron emitter labeled radiopharmaceuticals (PET radiopharmaceuticals) in the body. Positrons (ß+) are positively charged beta particles. They are emitted when the atom is proton rich. A positron has only a transient existence. After losing all of its kinetic ene...

متن کامل

PET Radiopharmaceuticals

PET (positron emission tomography) is a powerful imaging technique that can provide quantitative information on the distribution of positron emitter labeled radiopharmaceuticals (PET radiopharmaceuticals) in the body. Positrons (ß+) are positively charged beta particles. They are emitted when the atom is proton rich. A positron has only a transient existence. After losing all of its kinetic ene...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Imaging of accidental contamination with F-18-solution; a quick trouble-shooting procedure

 To the best of our knowledge, imaging of accidental exposure to radioactive fluorine-18 (F-18) due to liquid spill has not been described earlier in the scientific literature. The short half-life of F-18 (t½=110 min), current radiation safety requirements, and Good Manufacturing Practice (GMP) regulations on radiopharmaceuticals have restrained the occurrence of these incidents. The possibilit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004