BACKGROUND Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads. METHODS A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling. RESULTS At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose. CONCLUSIONS On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.
منابع مشابه
Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty.
BACKGROUND While most reports of component fracture following alumina-on-alumina total hip arthroplasty have involved the acetabular liner, few have involved fracture of the alumina femoral head. In the present multicenter study, we investigated ceramic head fractures in a cohort of patients who underwent third-generation alumina-on-alumina total hip arthroplasty. METHODS We performed a retro...
متن کاملAlumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report.
We previously reported the five-to-six-year results of the use of third-generation alumina-on-alumina bearings in a consecutive series of 100 primary cementless total hip arthroplasties. This report presents the longer-term outcomes of these same bearings, at a minimum of ten years postoperatively. Eighty-six of eighty-eight hips available for the study retained the original bearings at the tim...
متن کاملAlumina ceramic-on-ceramic total hip replacement with a layered acetabular component.
A modular layered acetabular component (metal-polyethylene-ceramic) was developed in Japan for use in alumina ceramic-on-ceramic total hip replacement. Between May 1999 and July 2000, we performed 35 alumina ceramic-on-ceramic total hip replacements in 30 consecutive patients, using this layered component and evaluated the clinical and radiological results over a mean follow-up of 5.8 years (5 ...
متن کاملFracture of the alumina-bearing couple delta ceramic liner.
The fracture rate of third-generation ceramic liners is greatly reduced compared with first- and second-generation liners because of improvements in the design and manufacturing process. Fractures of the alumina-bearing couple are rare for the same reason.This article describes a case of a fracture of an alumina-bearing couple delta ceramic liner without trauma history that was treated with cer...
متن کاملCeramic failure after total hip arthroplasty with an alumina-on-alumina bearing.
BACKGROUND The mechanical properties of alumina ceramic, now in its third generation, have been markedly improved through the evolution of design features and manufacturing processes and the introduction of proof-testing. Nonetheless, because of the lack of ductility of alumina ceramic, there is concern regarding the risk of fracture during insertion or in vivo use. The purpose of the present s...