Fitting a Model to Data in Loss Tomography
نویسنده
چکیده
Loss tomography has received considerable attention in recent years and a number of estimators have been proposed. Although most of the estimators claim to be the maximum likelihood estimators, the claim is only partially true since the maximum likelihood estimate can be obtained at most for a class of data sets. Unfortunately, few people are aware of this restriction that leads to a misconception that an estimator is applicable to all data sets as far as it returns a unique solution. To correct this, we in this paper point out the risk of this misconception and illustrate the inconsistency between data and model in the most influential estimators. To ensure the model used in estimation consistent with the data collected from an experiment, the data sets used in estimation are divided into 4 classes according to the characteristics of observations. Based on the classification, the validity of an estimator is defined and the validity of the most influential estimators is evaluated. In addition, a number of estimators are proposed, one for a class of data sets that have been overlooked. Further, a general estimator is proposed that is applicable to all data classes. The discussion starts from the tree topology and end at the general topology.
منابع مشابه
Velocity Inversion with an Iterative Normal Incidence Point (NIP) Wave Tomography with Model-Based Common Diffraction Surface (CDS) Stack
Normal Incidence Point (NIP) wave tomography inversion has been recently developed to generate a velocity model using Common Reflection Surface (CRS) attributes, which is called the kinematic wavefield attribute. In this paper, we propose to use the model based Common Diffraction Surface (CDS) stack method attributes instead of data driven Common Reflection Surface attributes as an input data p...
متن کاملProbability Distribution Fitting to Maternal Mortality in Nigeria.
The consequences of Maternal Mortality (MM) cannot be overemphasized. It inhibits population growth resulting into loss of lives among others. This work tends to obtain the maternal mortality rates (MMR) in Nigeria, identify some fitted distributions to MMR and determine which of the distributions best fits the data. A comprehensive Exploratory Data Analysis (EDA) was carried on MM and the MMRs...
متن کاملFitting of Count Time Series Models on the Number of Patients Referred to Addiction Treatment Centers in Semnan County
Abstract. Count data over time are observed in many application areas. Many researchers use time series patterns to analyze this data. In this paper, the poisson count time series linear models and negative binomials on this type of data with the explanatory variables are studied. The Likelihood analysis and the evaluation of count time series model based on generalized linear models are pres...
متن کاملModel-Fitting Approach to Kinetic Analysis of Non-Isothermal Oxidation of Molybdenite
The kinetics of molybdenite oxidation was studied by non-isothermal TGA-DTA with heating rate 5 ºC.min-1.The model-fitting kinetic approach applied to TGA data .The Coats-Redfern method used for model fitting. The popular model-fitting gives excellent fit for non-isothermal data in chemically controlled regime. The apparent activation energy was determined to be about 34.2 kcalmo...
متن کاملبررسی ارتباط بین ضخامت مخاط سینوس ماگزیلاری و با استفاده از periodontal bone loss Cone beam computed tomography
Introduction: Odontogenic infections are one of the common cause of maxillary sinusitis. This study aimed to evaluate the relationship between the teeth with periapical lesions or periodontal disease and sinus mucosal thickening using cone-beam computed tomography(CBCT). Methods: This was a retrospective and cross-sectional study. CBCT scans of 97 patients(188 sinuses) were evaluated retrospec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1107.3879 شماره
صفحات -
تاریخ انتشار 2011