Cardiac resynchronization therapy device implantation using a new sensor-based navigation system: results from the first human use study.

نویسندگان

  • Sergio Richter
  • Michael Döring
  • Thomas Gaspar
  • Silke John
  • Sascha Rolf
  • Philipp Sommer
  • Gerhard Hindricks
  • Christopher Piorkowski
چکیده

BACKGROUND Cardiac resynchronization therapy (CRT) device implantation can be challenging, time consuming, and fluoroscopy intense. To facilitate left ventricular lead placement, a novel sensor-based electromagnetic tracking system (MediGuide Technology [MGT], St. Jude Medical) has been developed. We report the results of the First Human Use study evaluating the feasibility, safety, and performance of a novel CRT implantation approach using electromagnetic trackable operation equipment. METHODS AND RESULTS Fifteen consecutive patients (66±8 years, 53% male) with an established indication for CRT were implanted using the new tracking technology. Demographics, anatomical information, detailed fluoroscopy need, procedure time, and adverse events were collected. Patients were followed up for 4 weeks after implantation. The CRT system was successfully implanted with a lateral or posterolateral left ventricular lead position in all patients. The total procedure time was 116±43 minutes, the median total fluoroscopy time (skin to skin) was 5.2 (Q1-Q3, 3.0-8.4) minutes, and the median fluoroscopy time for left ventricular lead deployment (coronary sinus [CS] cannulation to withdrawal of CS sheath) measured 2.6 (Q1-Q3, 1.6-5.6) minutes. There were no severe complications that required an acute intervention or reoperation during the perioperative and postoperative periods. CONCLUSIONS Use of the MGT tracking technology allows for safe and successful CRT implantation with the potential for reduced fluoroscopy time. Future randomized studies are needed to validate these data. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01519739.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantation of a biventricular implantable cardioverter-defibrillator guided by an electroanatomic mapping system

AIMS The aim of this study is to show the feasibility of a biventricular implantable cardioverter-defibrillator [cardiac resynchronization therapy (CRT)-ICD] implantation using an electroanatomic navigation system and a low dose of fluoroscopy. Here four case reports of patients affected by dilated cardiomyopathy, who underwent cardiac resynchronization therapy, are described. METHODS AND RES...

متن کامل

The clinical benefit of cardiac resynchronization therapy optimization using a device-based hemodynamic sensor in a patient with dilated cardiomyopathy: a case report

INTRODUCTION Results on the evolution of the clinical status of patients undergoing cardiac resynchronization therapy with a defibrillator after automatic optimization of their cardiac resynchronization therapy are scarce. We observed a rapid and important change in the clinical status of our non-responding patient following activation of a sensor capable of weekly atrioventricular and interven...

متن کامل

GPS Jamming Detection in UAV Navigation Using Visual Odometry and HOD Trajectory Descriptor

Auto-navigating of unmanned aerial vehicles (UAV) in the outdoor environment is performed by using the Global positioning system (GPS) receiver. The power of the GPS signal on the earth surface is very low. This can affect the performance of GPS receivers in the environments contaminated with the other source of radio frequency interference (RFI). GPS jamming and spoofing are the most serious a...

متن کامل

A Hierarchical SLAM/GPS/INS Sensor Fusion with WLFP for Flying Robo-SAR's Navigation

In this paper, we present the results of a hierarchical SLAM/GPS/INS/WLFP sensor fusion to be used in navigation system devices. Due to low quality of the inertial sensors, even a short-term GPS failure can lower the integrated navigation performance significantly. In addition, in GPS denied environments, most navigation systems need a separate assisting resource, in order to increase the avail...

متن کامل

Heart failure monitoring with a cardiac resynchronization therapy device-based cardiac contractility sensor: a case series

INTRODUCTION The SonR signal has been shown to reflect cardiac contractility. It is recorded with an atrial lead connected to a cardiac resynchronization therapy defibrillator. For the first time, clinical evidence on the use of the SonR signal in the monitoring of the clinical status of heart failure patients implanted with cardiac resynchronization therapy defibrillator are presented through ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 6 5  شماره 

صفحات  -

تاریخ انتشار 2013