Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
نویسندگان
چکیده
BACKGROUND To assess repeatability of the Zhongshan Assessment Program (ZAP) software measurement of Anterior Segment Optical Coherence Tomography (ASOCT) images and correlate with graft trephine diameter following Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) METHODS: Retrospectively evaluated interventional case series. 121 consecutive eyes undergoing DSAEK over a 26 month period underwent ASOCT imaging 1 month after their surgery. ASOCT images were processed using ZAP software which measured the graft and cornea parameters including anterior and posterior graft arc length and cord length, posterior cornea arc length (PCAL) and anterior chamber width. RESULTS The graft measurements showed good repeatability on ASOCT using ZAP with high intra class coefficient and small variation in the coefficient of variation. On ASOCT, the mean recipient PCAL was 12.99+/-0.69 mm and the anterior chamber width was 11.16+/-0.57 mm. The mean Graft anterior arc length was 9.69+/-0.66 mm and the mean Graft anterior cord length was 8.92+/-2.94 mm. The mean graft posterior arc length was 9.24+/-0.75 mm and the mean graft posterior cord length was 8.15+/-0.57 mm. Graft posterior arc length (rho=0.788, p< 0.001) correlated best with intra-operative graft trephine diameter. The mean ratio of posterior graft arc length to PCAL was 0.712 +/- 0.056. CONCLUSIONS We have validated the repeatability of the ZAP software for DSAEK graft measurements from ASOCT images and shown that the graft arc length parameters calculated from the ASOCT images correlate well with the intra-operative graft trephine diameter. This software may help surgeons determine the optimal DSAEK graft size based on pre-operative ASOCT measurements of the recipient eye.
منابع مشابه
Descemet stripping automated endothelial keratoplasty in Fuchs’ corneal endothelial dystrophy: anterior segment optical coherence tomography and in vivo confocal microscopy analysis
BACKGROUND To evaluate the in vivo corneal changes using in vivo confocal microscopy (IVCM) and anterior segment optical coherence tomography (AS-OCT) in patients with Fuchs' dystrophy who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) and the relationship between these changes and the postoperative visual recovery up to 1-year follow-up. METHODS Before DSAEK and 1 da...
متن کاملGraft Suturing for Lenticule Dislocation after Descemet Stripping Automated Endothelial Keratoplasty
PURPOSE To report the mid-term outcomes of graft suturing in a patient with lenticule dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK). CASE REPORT A 78-year old woman was found to have graft dislocation involving the nasal half of the cornea after uneventful DSAEK. Graft repositioning, refilling the anterior chamber with air, and placement of four full-thicknes...
متن کاملAutomated volumetric analysis of interface fluid in descemet stripping automated endothelial keratoplasty using intraoperative optical coherence tomography.
PURPOSE We demonstrated a novel automated algorithm for segmentation of intraoperative optical coherence tomography (iOCT) imaging of fluid interface gap in Descemet stripping automated endothelial keratoplasty (DSAEK) and evaluated the effect of intraoperative maneuvers to promote graft apposition on interface dimensions. METHODS A total of 30 eyes of 29 patients from the anterior segment ar...
متن کاملRepair of descemet membrane detachments with the assistance of anterior segment optical coherence tomography.
Extensive Descemet membrane detachment (DMD) is a rare complication of intraocular surgery that can lead to corneal decompensation. Although DMD may resolve spontaneously, surgical repair frequently is required. The diagnosis may be difficult because corneal edema can obscure visualization of the Descemet membrane (DM). Ultrasonographic biomicroscopy (UBM) has been the standard for imaging DMD ...
متن کاملFemtosecond laser and microkeratome-assisted Descemet stripping endothelial keratoplasty: first clinical results.
AIM To perform Descemet stripping automated endothelial keratoplasty (DSAEK) using a novel technique to obtain very thin (<100 µm) posterior corneal disks. METHODS Twenty five DSAEK grafts were prepared with two sequential cuts: the first cut, of variable thickness, was made with a femtosecond laser and the second with a 300 µm microkeratome head. Spectacle corrected visual acuity, endothelia...
متن کامل