Application of a circulating-cathodic-antigen (CCA) strip test and real-time PCR, in comparison with microscopy, for the detection of Schistosoma haematobium in urine samples from Ghana.

نویسندگان

  • B B Obeng
  • Y A Aryeetey
  • C J de Dood
  • A S Amoah
  • I A Larbi
  • A M Deelder
  • M Yazdanbakhsh
  • F C Hartgers
  • D A Boakye
  • J J Verweij
  • G J van Dam
  • L van Lieshout
چکیده

In the detection of parasitic infection, the traditional methods based on microscopy often have low sensitivity and/or specificity compared with the newer, molecular tests. An assay based on real-time PCR and a reagent strip test for detecting circulating cathodic antigen (CCA) have both now been compared with urine filtration and microscopy, in the detection of Schistosoma haematobium infections. Urine samples, obtained from 74 'cases' in areas of Ghana with endemic S. haematobium and 79 'controls' from non-endemic areas, were each checked using the three methods. With the results of the filtration and microscopy taken as the 'gold standard', real-time PCR was found to be 100% specific and 89% sensitive whereas the CCA strips were 91% specific and 41% sensitive. With the samples found to contain > or =50 eggs/10 ml (indicating relatively intense infections), the sensitivities of the PCR and CCA were higher, at 100% and 62%, respectively. As expected, egg counts were negatively correlated with the number of amplification cycles needed, in the PCR, to give a signal that exceeded the background (r=-0.38; P<0.01). Although the real-time PCR and CCA strip tests are very different, both show promise in the detection of S. haematobium infections. The PCR has optimal specificity and high sensitivity but the specificity of the CCA strips and the sensitivity of both tools could still be improved. A more thorough re-evaluation of the sensitivity and specificity of microscopy and these newer diagnostic methods, with an estimation of the cost-effectiveness of each technique, is recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Circulating Cathodic Antigen (CCA) Urine-Tests for Diagnosis of Schistosoma mansoni Infection in Cameroon

BACKGROUND The Kato-Katz is the most common diagnostic method for Schistosoma mansoni infection. However, the day-to-day variability in host egg-excretion and its low detection sensitivity are major limits for its use in low transmission zones and after widespread chemotherapy. We evaluated the accuracy of circulating cathodic antigen (CCA) urine-assay as a diagnostic tool of S. mansoni. In com...

متن کامل

Prevalence of urinary schistosomiasis in Egypt: result of a study in high versus low endemic governorates

Schistosomiasis is one of the most prevalent parasitic infections worldwide. Establishment of sensitive assays to detect schistosomiasis in situations with low transmission is crucial. The present study aimed to estimate the current status of S. haematobium infection in different Egyptian localities. Urine samples were collected from 960 asymptomatic men from Great Cairo (low-endemic) and Fayou...

متن کامل

Accuracy of circulating cathodic antigen tests for rapid mapping of Schistosoma mansoni and S. haematobium infections in Southern Sudan.

OBJECTIVE To evaluate the diagnostic accuracy of a circulating cathodic antigen (CCA) urine dipstick test for detecting Schistosoma mansoni and S. haematobium alongside an integrated rapid mapping survey in Southern Sudan. METHODS AND RESULTS A total of 373 children aged 5-16 years were included in the study. Of these 26.0% were infected with S. haematobium and 24.5% were infected with S. man...

متن کامل

Validation of a Point-of-Care Circulating Cathodic Antigen Urine Cassette Test for Schistosoma mansoni Diagnosis in the Sahel, and Potential Cross-Reaction in Pregnancy.

On the shores of Lake Chad, schistosomiasis among mobile pastoralists was investigated in a field laboratory. Point-of-care circulating cathodic antigen (POC-CCA) cassette test, reagent strip, and filtration were conducted on urine samples. Fresh stool samples were subjected to the Kato-Katz technique, and fixed samples were examined with an ether-concentration method at a reference laboratory....

متن کامل

Evaluation of circulating cathodic antigen (CCA) strip for diagnosis of urinary schistosomiasis in Hassoba school children, Afar, Ethiopia.

A total of 206 urine samples collected from Hassoba Elementary schoolchildren, Afar, Ethiopia, a low Schistosoma haematobium endemic setting, was diagnosed to evaluate the performance of CCA strip using double references, urine filtration technique and urinalysis dipstick (Combur 1.0 Test) that detect schistosome eggs and blood in urine, respectively. The former was used as a gold standard refe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of tropical medicine and parasitology

دوره 102 7  شماره 

صفحات  -

تاریخ انتشار 2008