Characterization of a 137 Cs standard source for calibration purposes at

نویسندگان

  • Mércia L Oliveira
  • Marcus Aurélio P dos Santos
  • Clayton A Benevides
  • Luiz Freire
چکیده

Radiation protection monitoring instruments should be calibrated by accredited calibration laboratories. To offer calibration services, a laboratory must accomplish all requirements established by the national regulatory agency. The Calibration Service of the Centro Regional de Ciências Nucleares (CRCN-NE), Comissão Nacional de Energia Nuclear, Recife, Brazil, is trying to achieve this accreditation. In the present work, a Cs standard source was characterized following the national and international recommendations and the results are presented. This source is a commercially available single source irradiator model 28-8A, manufactured by JLShepherd & Associates, with initial activity of 444 GBq (05/13/03). To provide different air kerma rates, as required for the calibration of portable radiation monitors, this irradiator have a set of four lead attenuators with different thickness, providing attenuation factors equal to 2, 4, 10 and 100 times (nominally). The performed tests included: size and uniformity of the radiation standard field at calibration reference position, variation of the air kerma rate for different lead attenuators, determination of attenuation factors for each lead attenuator configuration, and determination of the radiation scattering at the calibration reference position. The results showed the usefulness of the Cs standard source for the calibration of radiation protection monitoring detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TITLE: Air Kerma Primary Standard: Experimental and Simulation Studies on Cs-137

The primary standard for air kerma for the gamma radiation of Cs-137, of the Metrological Laboratory of Ionising Radiation (LMRI), is an ionisation chamber of the type CC01. This instrument was, for the first time, used to characterize the radiation field, in terms of air kerma, produced by a Cs-137 source in an irradiator Shepherd model 81, used mainly for radiation protection calibration purp...

متن کامل

Preliminary Investigations of the Contribution of Scatter Radiation During Calibration of TLD-100 Using a Cs-137 Panoramic Source

Studies were carried out to determine the contribution of secondary photons to the calibration set-up of a Secondary Standard Dosimetry Laboratory. In these studies the response of LiF:Mg TLD-100 to known exposures using Cs-137 panoramic-source were investigated. Each TLD chip showed a linear dose response to radiation, demonstrating a typical characteristic of LiF:Mg chips. Whilst TLDs showed ...

متن کامل

Investigation of Anisotropy Caused by Cylinder Applicator on Dose Distribution around Cs-137 Brachytherapy Source using MCNP4C Code

Introduction: Brachytherapy is a type of radiotherapy in which radioactive sources are used in proximity of tumors normally for treatment of malignancies in the head, prostate and cervix. Materials and Methods: The Cs-137 Selectron source is a low-dose-rate (LDR) brachytherapy source used in a remote afterloading system for treatment of different cancers. This system uses active and inactive sp...

متن کامل

A New Approach for Heterogeneity Corrections for Cs-137 Brachytherapy Sources

Background: Most of the current brachytherapy treatment planning systems (TPS) use the TG-43U1 recommendations for dosimetry in water phantom, not considering the heterogeneity effects.Objective: The purpose of this study is developing a method for obtaining correction factors for heterogeneity for Cs-137 brachytherapy sources based on pre-calculated MC simulations and interpolation.Method: To ...

متن کامل

The photon fluence non-uniformity correction for air kerma near Cs-137 brachytherapy sources.

The use of brachytherapy sources in radiation oncology requires their proper calibration to guarantee the correctness of the dose delivered to the treatment volume of a patient. One of the elements to take into account in the dose calculation formalism is the non-uniformity of the photon fluence due to the beam divergence that causes a steep dose gradient near the source. The correction factors...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008