Tremor stability index: a new tool for differential diagnosis in tremor syndromes

نویسندگان

  • Lazzaro di Biase
  • John-Stuart Brittain
  • Syed Ahmar Shah
  • David J. Pedrosa
  • Hayriye Cagnan
  • Alexandre Mathy
  • Chiung Chu Chen
  • Juan Francisco Martín-Rodríguez
  • Pablo Mir
  • Lars Timmerman
  • Petra Schwingenschuh
  • Kailash Bhatia
  • Vincenzo Di Lazzaro
  • Peter Brown
چکیده

See Vidailhet et al. (doi:10.1093/brain/awx140) for a scientific commentary on this article.Misdiagnosis among tremor syndromes is common, and can impact on both clinical care and research. To date no validated neurophysiological technique is available that has proven to have good classification performance, and the diagnostic gold standard is the clinical evaluation made by a movement disorders expert. We present a robust new neurophysiological measure, the tremor stability index, which can discriminate Parkinson's disease tremor and essential tremor with high diagnostic accuracy. The tremor stability index is derived from kinematic measurements of tremulous activity. It was assessed in a test cohort comprising 16 rest tremor recordings in tremor-dominant Parkinson's disease and 20 postural tremor recordings in essential tremor, and validated on a second, independent cohort comprising a further 55 tremulous Parkinson's disease and essential tremor recordings. Clinical diagnosis was used as gold standard. One hundred seconds of tremor recording were selected for analysis in each patient. The classification accuracy of the new index was assessed by binary logistic regression and by receiver operating characteristic analysis. The diagnostic performance was examined by calculating the sensitivity, specificity, accuracy, likelihood ratio positive, likelihood ratio negative, area under the receiver operating characteristic curve, and by cross-validation. Tremor stability index with a cut-off of 1.05 gave good classification performance for Parkinson's disease tremor and essential tremor, in both test and validation datasets. Tremor stability index maximum sensitivity, specificity and accuracy were 95%, 95% and 92%, respectively. Receiver operating characteristic analysis showed an area under the curve of 0.916 (95% confidence interval 0.797-1.000) for the test dataset and a value of 0.855 (95% confidence interval 0.754-0.957) for the validation dataset. Classification accuracy proved independent of recording device and posture. The tremor stability index can aid in the differential diagnosis of the two most common tremor types. It has a high diagnostic accuracy, can be derived from short, cheap, widely available and non-invasive tremor recordings, and is independent of operator or postural context in its interpretation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis and differential diagnosis of Parkinson's disease and parkinsonism.

In the clinic setting, most cases represent either Parkinson's disease (PD) or one of the other neurodegenerative disorders that make up the parkinsonism-plus syndromes. The major parkinsonism-plus syndromes include progressive supranuclear palsy, multiple system atrophy, corticobasal degeneration, as well as parkinsonism occurring in the context of Alzheimer's disease or one of the other prima...

متن کامل

Laryngoscopy evaluation protocol for the differentiation of essential and dystonic voice tremor.

INTRODUCTION Although syndromes that cause voice tremor have singular characteristics, the differential diagnosis of these diseases is a challenge because of the overlap of the existing signs and symptoms. OBJECTIVE To develop a task-specific protocol to assess voice tremor by means of nasofibrolaryngoscopy and to identify those tasks that can distinguish between essential and dystonic tremor...

متن کامل

Differential diagnosis of common tremor syndromes.

Tremor is one of the most common involuntary movement disorders seen in clinical practice. In addition to the detailed history, the differential diagnosis is mainly clinical based on the distinction at rest, postural and intention, activation condition, frequency, and topographical distribution. The causes of tremor are heterogeneous and it can present alone (for example, essential tremor) or a...

متن کامل

Optimal design of a vibration absorber for tremor control of arm in Parkinson's disease

Because the underlying physiology of pathological tremor in a Parkinson's patient is not well understood, the existing physical and drug therapies have not been successful in tremor treatment. Different mathematical modeling of such vibration has been introduced to investigate the problem and reduce the existing vibration. Most of the models have represented the induced vibration as a sinusoida...

متن کامل

Positron Emission Tomography in the Differential Diagnosis of Parkinsonism

Positron emission tomography (PET) studies on presynaptic dopaminergic function can reveal hypofunction in early Parkinson's disease (PD) which may help in the early diagnosis especially in patients with mild symptoms. This hypofunction can be detected with fluorodopa (reflecting mainly aromatic amino acid decarboxylase activity of nigrostriatal terminals) or dopamine transporter ligands. These...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 140  شماره 

صفحات  -

تاریخ انتشار 2017