Fiber optic sensors using novel substrates for hydrogen sulfide determination by solid surface fluorescence.
نویسندگان
چکیده
Two different fiber optic sensors were developed for the determination of hydrogen sulfide at ppb concentration levels; a probe-type fiber optic sensor coated with polyethylene oxide containing 0.5 M CdCl(2) and a fiber optic sensor utilizing 0.5 M CdCl(2)-pretreated filter paper as solid substrate. In the first type, CdCl(2)-polyethyleneoxide (PEO) mixture was coated onto the tip of a fiber optic probe and the probe was exposed to H(2)S. The methodology is based on the measurement of CdS fluorescence on the surface. Detection limit (3s) of the PEO-coated fiber optic system was 36.0 ppb for H(2)S and precision at the 0.552 ppm level was 29% R.S.D. For the fiber optic system utilizing CdCl(2)-pretreated filter paper, two different configurations were devised and evaluated; a bifurcated fiber optic sensor and a single fiber optic sensor. Similar figures were obtained with these two systems; the detection limit (3s) was 4.0 ppb for the bifurcated fiber optic sensor and 4.3 ppb for the single fiber optic sensor, and both sensors had linear responses in the range 0.032-1.0 ppm. Their precisions at 0.299 ppm level were also very similar, 10 and 11% R.S.D., respectively, for the bifurcated and single fiber systems. In addition to the fiber optic sensors developed, various surfactants (sodiumdodecylsulfate (SDS), Aerosol OT, Aerosol A102, Aerosol 501), some cellulosic substances (sodium carboxymethylcellulose (CMC), ethylcellulose, hydroxypropylmethylcellulose, ethylhydroxyethylcellulose, alpha-cellulose) and several water-soluble polymers (polyacrylicacid polyethleneoxide (PEO), polyvinylalcohol (PVA)) were dissolved in proper solvents and after mixing with 0.5 M CdCl(2), were spread over glass slides. These novel solid substrates were exposed to H(2)S and fluorescence signal on the surfaces of the glass slides was measured with a luminescence spectrometer. The new substrates were shown to be good alternatives to filter paper for the determination of H(2)S by room temperature solid surface fluorescence spectrometry.
منابع مشابه
A novel sorbent tube for ambient hydrogen sulfide determination.
A novel tubular device has been developed for hydrogen sulfide determination in air. Several substrates such as commercial silica gel and alumina TLC plates, silica gel powder, alumina, CaSO(4), CaCO(3), BaSO(4), MgO, chalk, alpha-cellulose and ethyl cellulose were tested as solid substrates. 30-70-mesh silica gel was finally employed in glass tubes of 4.0 mm internal diameter. Silica gel is tr...
متن کاملCOMPARISON OF DIFFERENT GLASS COMPOUNDS FOR INTRINSIC FIBER OPTIC TEMPERATURE SENSORS
Different glasses suitable for temperature sensing in the fiber optic sensors were studied in this article. The phase changes for eight different glass materials were calculated and results were compared. Our results showed that extra dense flint glass is the most sensitive one, while pure silica results in the lowest phase change. In another study the effect of wavelength on the phase variatio...
متن کاملHCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction
In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...
متن کاملEmployment of Fluorescence Quenching for the Determination of Oxygen and Glucose
The measurement of fluorescence quenching activity of [Ru(L)3] with 4,7-diphenyl1,10 phenanthroline (dip) on silica gel and embedded in polystyrene polymers for the determination of dissolved oxygen using fiber optic probe is described here. The system is extended by immobilization of glucose oxidaze (GOD) for the determination of glucose. The objective of the work is to conquer the leaching an...
متن کاملFiber-Optic Fluorescence Carbon Dioxide Sensor for Environmental Monitoring
Fiber-optic sensors were developed for monitoring dissolved carbon dioxide in water samples in the 0 to 900 ppm concentration range. A pH-sensitive fluorescent dye (HPTS) was reacted with a cationic quaternary ammonium salt to form an ion pair which was electrostatically bound to the surface of particles of aminocellulose which then were dispersed into a gas-permeable silicone polymer. The gree...