Determination of polychlorinated biphenyls in soil and sediment by selective pressurized liquid extraction with immunochemical detection.

نویسندگان

  • Jeanette M Van Emon
  • Jane C Chuang
  • Alisa Bronshtein
  • Miriam Altstein
چکیده

A selective pressurized liquid extraction (SPLE) method was developed for a streamlined sample preparation/cleanup to determine Aroclors and coplanar polychlorinated biphenyls (PCBs) in soil and sediment. The SPLE was coupled with an enzyme-linked immunosorbent assay (ELISA) for an effective analytical approach for environmental monitoring. Sediment or soil samples were extracted with alumina, 10% AgNO3 in silica, and sulfuric acid impregnated silica with dichloromethane at 100°C and 2000 psi. The SPLE offered simultaneous extraction and cleanup of the PCBs and Aroclors, eliminating the need for a post-extraction cleanup prior to ELISA. Two different ELISA methods: (1) an Aroclor ELISA and (2) a coplanar PCB ELISA were evaluated. The Aroclor ELISA utilized a polyclonal antibody (Ab) with Aroclor 1254 as the calibrant and the coplanar PCB ELISA kit used a rabbit coplanar PCB Ab with PCB-126 as the calibrant. Recoveries of Aroclor 1254 in two reference soil samples were 92±2% and 106±5% by off-line coupling of SPLE with ELISA. The average recovery of Aroclor 1254 in spiked soil and sediment samples was 92±17%. Quantitative recoveries of coplanar PCBs (107-117%) in spiked samples were obtained with the combined SPLE-ELISA. The estimated method detection limit was 10 ng g(-1) for Aroclor 1254 and 125 pg g(-1) for PCB-126. Estimated sample throughput for the SPLE-ELISA was about twice that of the stepwise extraction/cleanup needed for gas chromatography (GC) or GC/mass spectrometry (MS) detection. ELISA-derived uncorrected and corrected Aroclor 1254 levels correlated well (r=0.9973 and 0.9996) with the total Aroclor concentrations as measured by GC for samples from five different contaminated sites. ELISA-derived PCB-126 concentrations were higher than the sums of the 12 coplanar PCBs generated by GC/MS with a positive correlation (r=0.9441). Results indicate that the SPLE-ELISA approach can be used for quantitative or qualitative analysis of PCBs in soil and sediments. To our knowledge, this is the first report of an SPLE-ELISA approach not requiring a post-extraction cleanup step for detecting Aroclors and coplanar PCBs in soil and sediment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective pressurized liquid extraction of polychlorinated biphenyls in sediment.

A selective pressurized liquid extraction procedure (SPLE) was developed for a fast determination of polychlorinated biphenyls in sediment. The final method was performed at 100 degrees C with heptane/dichloromethane (90:10, v/v) as extraction solvent for 2x5 min. Sulfuric acid impregnated silica was placed downstream of the sample in the extraction cell to remove interfering components. This s...

متن کامل

Optimization of pressurized liquid extraction (PLE) of dioxin-furans and dioxin-like PCBs from environmental samples.

Pressurized liquid extraction (PLE) applying three extraction cycles, temperature and pressure, improved the efficiency of solvent extraction when compared with the classical Soxhlet extraction. Polychlorinated-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like PCBs (coplanar polychlorinated biphenyls (Co-PCBs)) in two Certified Reference Materials [DX-1 (sediment) and BCR...

متن کامل

Biodegradation of Polychlorinated Biphenyls by and Isolated from Contaminated Soil

Polychlorinated biphenyls (PCBs) cause many significant ecological problems because of their low degradability, high harmfulness, and solid bioaccumulation.Two bacterial strains were isolated from soil that had been polluted with electrical transformer liquid for more than 40 years. The isolates were distinguished as Lysinibacillus macrolides DSM54Tand Bacillus firmus NBRC1530...

متن کامل

Analysis, source identification and health risk assessment of polychlorinated biphenyls (PCBs) in surface soils from different land types of northern, eastern and western parts of city of Tehran, Iran

Polychlorinated biphenyls (PCBs) are a group of persistent organic pollutants that due to their characteristics including bioaccumulation potential and persistence in the environment; can pose adverse effects on human and environmental health. Therefore, this study was performed to analysis, source identification and health risk assessment of PCBs in surface soil samples collected from some lan...

متن کامل

Immunochemical determination of dioxins in sediment and serum samples.

Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants and the environmental and biological monitoring of these compounds is of great concern. Immunoassays may be used as screening methods to satisfy the growing demand for rapid and low cost analysis. In this work, we describe the application of an immunoassay that uses 2,3,7...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 463-464  شماره 

صفحات  -

تاریخ انتشار 2013