Notes on Neutron Depth Profiling

نویسندگان

  • J. K. Shultis
  • J. Kenneth Shultis
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutron Depth Profiling: Overview and Description of NIST Facilities

The Cold Neutron Depth Profiling (CNDP) instrument at the NIST Cold Neutron Research Facility (CNRF) is now operational. The neutron beam originates from a 16 L D2O ice cold source and passes through a filter of 135 mm of single crystal sapphire. The neutron energy spectrum may be described by a 65 K Maxwellian distribution. The sample chamber configuration allows for remote controlled scanning...

متن کامل

Glow Discharge Depth Profiling a Powerful Analytical Technique in Surface Engineering (TECHNICAL NOTE)

A variety of analytical techniques have been developed and employed to characterize the surfaces, subsurfaces and interfaces of surface engineering systems. They provide important information for quality control, process optimization and further development. Since the mid 1980's, glow discharge spectrometry (GDS) has emerged as an important and versatile technique for rapid depth profiling anal...

متن کامل

Computation and inversion of ion spectra for neutron depth profiling of curved surfaces

Neutron depth profiling (NDP) is a nondestructive technique for determining the concentration of special isotopes within several microns of a sample’s surface. Previous NDP analyses, however, have been restricted to samples with plane surfaces. Here samples with curved surfaces are considered. In particular, a method for estimating the energy spectrum of ions emitted from curved surfaces is pre...

متن کامل

Assessment of secondary neutron dose due to dental restorations in head and neck radiation therapy

Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...

متن کامل

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004