Recent advances in 3D time-resolved contrast-enhanced MR angiography.
نویسندگان
چکیده
Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The purpose of this work is to describe how this has been accomplished. Specific technical enablers have been: improved gradients allowing reduced repetition times, improved k-space sampling and reconstruction methods, parallel acquisition, particularly in two directions, and improved and higher count receiver coil arrays. These have collectively made high-resolution time-resolved studies readily available for many anatomic regions. Depending on the application, ∼1 mm isotropic resolution is now possible with frame times of several seconds. Clinical applications of time-resolved CE-MRA are briefly reviewed.
منابع مشابه
Preliminary experience using contrast-enhanced MR angiography to assess vertebral artery structure for the follow-up of suspected dissection.
BACKGROUND AND PURPOSE Important advances have been made recently in MR angiography with the use of contrast medium injection, which has proved valuable for the imaging of vertebral arteries (VAs) obtained during short scanning times. Our purpose was to assess the feasability of contrast-enhanced fast 3D MR angiography for imaging VAs and to evaluate the long-term follow-up of VA dissections. ...
متن کاملComprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-resolved Angiography With Interleaved Stochastic Trajectories (TWIST) with standard 3D contrast enhanced MR Angiography (ceMRA)
(A) TWIST image in early arterial phase showing capillary lakes (arrow head). (B) TWIST image 2.2 sec after (A) showing development of tiny early draining veins (arrow). (C) Standard 3d ceMRA in the arterial phase demonstrating significant venous contamination without evidence of capillary shunting. Comprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-...
متن کاملDistal Lower Extremities: Prospective Comparison of 2D Time-of-Flight, 3D Time-Resolved Contrast-Enhanced MR Angiography, and 3D Bolus Chase Contrast-Enhanced MR Angiography
W. Y. Hahn, E. M. Hecht, B. Friedman, V. S. Lee NYU Medical Center, New York, NY, United States SYNOPSIS: Magnetic resonance angiography of the calf and pedal arteries is challenging due to the issues of venous contamination and small vessel size. Therefore, contrast-enhanced MRA is typically supplemented with TOF imaging below the knee. In this study, we compared the conventional TOF sequence ...
متن کاملRecent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملTime-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE).
We describe a time-resolved, contrast-enhanced carotid MR angiographic technique using a 3D gradient-echo sequence in combination with a sensitivity-encoding scheme. We delineate the steps involved in generating the dynamic MR angiographic images, discuss issues related to image quality, and outline differences between this technique and recently reported similar methods that implement multiple...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2015