Diagnostic value of microtympanometry in primary care.
نویسنده
چکیده
OBJECTIVE To determine the reliability, validity, and feasibility of a new hand held microtympanometer. DESIGN Comparison of microtympanometry by two independent observations of a general practitioner and a nurse, and against a validated reference instrument. SETTING Primary care health centre of a school for the deaf in the United States. SUBJECTS 111 schoolchildren receiving a regular check up. MAIN OUTCOME MEASURES Tympanometry with the Grason Stadler 28, classified with a slightly modified Jerger's classification. RESULTS Interobserver reliability was 0.95 (Cohen's kappa). Results of microtympanometry were highly comparable with results of the reference instrument (likelihood ratio of positive results, 161.2). CONCLUSIONS The microtympanometer could be used in general practice: it is hand held, child friendly, easy to handle, and accurate.
منابع مشابه
Implementation of "Chronic Care Model" for Diabetes Care in Iranian Primary Health Care: Does it work?
Objective: Traditional health care systems were not capable to face successfully with chronic diseases including diabetes mellitus. In this regard, the Chronic Care Model or CCM was created to promote quality of care. The aim of this study was to examine whether establishment of chronic care model, with focus on diabetic patients, has led to clinically significant outcomes in Iran. Materials a...
متن کاملHow valid is the tallquist method in screening pregnant women with anemia in poor rural settings of southwestern Nigeria?
Background: Diagnosis of anemia is challenging in resource-poor settings due to inadequate laboratory resources. This study assessed the validity of the Tallquist haemoglobinometer in assessing anemia among pregnant women in Osogbo, Southwestern Nigeria. Methods: This was a cross - sectional study, in which 200 pregnant women of reproductive age were selected using multist...
متن کاملImproving Wait Times to Care for Individuals with Multimorbidities and Complex Conditions Using Value Stream Mapping
Background Recognizing the significant impact of wait times for care for individuals with complex chronic conditions, we applied a LEAN methodology, namely – an adaptation of Value Stream Mapping (VSM) to meet the needs of people with multiple chronic conditions and to improve wait times without additional resources or funding. Methods Over an 18-month time period, staff applied a patient-cen...
متن کاملDiagnostic performance of 18F-FDG PET-CT in patients presenting with secondary neck nodes from an unknown primary
Introduction: Clinical examination and even anatomical imaging may fail to identify primary site of malignancy in patients presenting with cervical nodal metastasis. 18F-Fluorodeoxyglucose Positron Emission Computed Tomography (18F-FDG PET-CT) is known to overcome the limitations of anatomic imaging. Methods: Sixty-three (63) patient...
متن کاملInfluence of the Different Primary Cancers and Different Types of Bone Metastasis on the Lesion-based Artificial Neural Network Value Calculated by a Computer-aided Diagnostic System,BONENAVI, on Bone Scintigraphy Images
Objective(s): BONENAVI, a computer-aided diagnostic system, is used in bone scintigraphy. This system provides the artificial neural network (ANN) and bone scan index (BSI) values. ANN is associated with the possibility of bone metastasis, while BSI is related to the amount of bone metastasis. The degree of uptake on bone scintigraphy can be affected by the type of bone metastasis. Therefore, t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMJ
دوره 304 6819 شماره
صفحات -
تاریخ انتشار 1992