On the Projection-Reconstruction NMR.∗
نویسنده
چکیده
We discuss the recently proposed Hybrid Backprojection/Lower-Value (HBLV) algorithm and its implementation in the NMR projection-reconstruction software PR-CALC. We argue that the HBLV reconstruction is only suitable for spectra that have no negative peaks. However, in such cases HBLV becomes a straight-forward generalization of the Lower-Value reconstruction algorithm and boils down to a simple calculation, not requiring an expensive combinatorial search for the smallest sum as was originally suggested by the authors.
منابع مشابه
Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملPR-CALC: a program for the reconstruction of NMR spectra from projections.
Projection-reconstruction NMR (PR-NMR) has attracted growing attention as a method for collecting multidimensional NMR data rapidly. The PR-NMR procedure involves measuring lower-dimensional projections of a higher-dimensional spectrum, which are then used for the mathematical reconstruction of the full spectrum. We describe here the program PR-CALC, for the reconstruction of NMR spectra from p...
متن کاملFast reconstruction of four-dimensional NMR spectra from plane projections.
Four-dimensional NMR spectroscopy can be speeded up by a large factor by a projection-reconstruction technique related to that used in X-ray tomography. The limited amount of information recorded in a few suitably-tilted projection planes suffices to recreate the entire four-dimensional spectrum. The method is demonstrated by reference to the 500 MHz spectrum of 1 millimolar aqueous solution of...
متن کاملImpact of reconstruction method on quantitative parameters of 99mTc-TRODAT-1 SPECT
Introduction: Quantitative evaluation is recommended to improve diagnostic ability and serial assessment of dopamine transporter (DAT) density scans. We decided to compare the ordered subsets expectation-maximization (OSEM) with filtered back-projection (FBP), and to investigate the impact of different iteration and cut-off frequencies on SBR values. Methods</stro...
متن کاملNipple Reconstruction Using the C-V Flap Technique: Long-Term Outcomes and Patient Satisfaction
BACKGROUND Nipple creation using the C-V flap technique is often the final step in breast reconstruction. The aim of this study was to subjectively and objectively assess the cosmetic outcomes and satisfaction of patients undergoing C-V flap nipple reconstruction. METHODS Subjective assessments of patient satisfaction with the neo-nipple were recorded by visual analogue scoring (VAS; 0...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007