Indigenously developed multipurpose acrylic head phantom for verification of IMRT using film and gel dosimetry

نویسندگان

  • N. Gopishankar
  • S. Vivekanandhan
  • G.K. Rath
  • M.A. Laviraj
  • S. Senthilkumaran
  • S.S. Kale
  • S. Thulkar
  • R.K. Bisht
  • V. Subramani
چکیده

The purpose of this study was to validate the newly designed acrylic phantom for routine dosimetric purpose in radiotherapy. The phantom can be used to evaluate and compare the calculated dose and measured dose using film and gel dosimetric methods. In this study, a doughnut-shaped planning target volume (8.54 cm3) and inner organ at risk (0.353 cm3) were delineated for an IMRT test plan using the X-ray CT image of the phantom. The phantom consists of acrylic slabs which are integrated to form a human head with a hole in the middle where several dosimetric inserts can be positioned for measurement. An inverse planning with nine coplanar intensity-modulated fields was created using Pinnacle TPS. For the film analysis, EBT2 film, flatbed scanner, in-house developed MATLAB codes and ImageJ software were used. The 3D dose distribution recorded in the MAGAT gel dosimeter was read using a 1.5 T MRI scanner. Scanning parameters were CPMG pulse sequence with 8 equidistant echoes, TR = 5600, echo step = 22 ms, pixel size = 0.5 × 0.5, slice thickness = 2 mm. Using a calibration relationship between absorbed dose and spin-spin relaxation rate (R2), R2 images were converted to dose images. The dose comparison was accomplished using in-house MATLAB-based graphical user interface named "IMRT3DCMP". For gel measurement dose grid from the TPS was extracted and compared with the measured dose grid of the gel. Gamma index analysis of film measurement for the tolerance criteria of 2%/2mm, 1%/1 mm showed more than 90% voxels pass rate. Gamma index analysis of 3D gel measurement data showed more than 90% voxels pass rate for different tolerance criteria of 2%/2 mm and 1%/1 mm. Overall both 2D and 3D measurement were in close agreement with the Pinnacle TPS calculated dose. The phantom designed is cost-effective and the results are promising, but further investigation is required to validate the phantom with other 3D conformal techniques for dosimetric purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification

Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

The use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique

Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...

متن کامل

Evaluation of Full scatter convolution algorithm based Treatment Planning System performance in the presence of inhomogeneities using three-dimensional film dosimetry

Introduction: Inclusion of inhomogeneities such as air-filled cavities in the head and neck treatment fields may result in potential dosimetric disagreement which was caused by electronic disequilibrium. Most of treatments planning systems (TPS) are not able to predict dose distribution of inhomogeneous regions accurately. EBT2 films are used frequently in radiotherapy quality ass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013