The role of sex and biochemical markers of inflammation in left ventricular remodelling, before and after surgery, in elderly patients with aortic valve stenosis.
نویسندگان
چکیده
INTRODUCTION The aim of this study was to determine whether sex and biochemical markers of inflammation have a role in left ventricular (LV) remodelling after aortic valve replacement in elderly patients with aortic valve stenosis. METHODS We studied 52 elderly patients with aortic valve stenosis (32 men, mean age 65 +/- 11 years and 20 women, mean age 68 +/- 9 years). Body surface area did not differ between men and women (1.81 +/- 0.15 versus 1.84 +/- 0.20, respectively). All patients underwent a complete echocardiographic examination for the determination of ejection fraction (EF), LV mass and mass index, peak and mean systolic pressure gradient, aortic valve area, early (E) and late (A) transmitral flow wave velocities and their ratio (E/A), tissue Doppler indexes of the mitral annulus (Sa, Ea, Aa), and the E/Ea ratio. In addition, levels of high sensitivity C-reactive protein (hsCRP), tumour necrosis factor-alpha (TNF-alpha) and monocyte chemoattractant protein-1 (MCP-1) were measured from venous blood samples taken before, and 10 days, 3 months and 6 months after aortic valve replacement. RESULTS LV mass decreased from 297 +/- 99.7 g before aortic valve replacement to 210 +/- 67 g 3 months after surgery and to 210 +/- 74 g 6 months after surgery (p<0.001). LV EF did not change significantly (p=0.836). Peak and mean systolic pressure gradients decreased, whereas aortic valve area increased after valve replacement (p<0.001). These changes were similar in men and women. In women Sa was greater (p=0.017) and the E/Ea ratio lower (p=0.025) than in men. The long-term changes in peak and mean pressure gradients, aortic valve area and LV mass after aortic valve replacement were well correlated with the long-term changes in hsCRP, TNF-alpha and MCP-1 in both men and women. CONCLUSIONS LV remodelling is similar in elderly men and women with aortic valve disease who have similar body surface area. Although inflammatory markers are not correlated with echocardiographic parameters before aortic valve replacement, a strong correlation exists after operation. This correlation is similar in men and women.
منابع مشابه
بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی
Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...
متن کاملعوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross
Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...
متن کاملRight ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease
Introduction: In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...
متن کاملDoppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Hellenic journal of cardiology : HJC = Hellenike kardiologike epitheorese
دوره 50 1 شماره
صفحات -
تاریخ انتشار 2009