Preconcentration and frontal electroelution of amino acids for in-line solid-phase extraction-capillary electrophoresis.

نویسنده

  • Michael C Breadmore
چکیده

A new frontal electroelution approach that can be used for the preconcentration of amino acids in in-line solid-phase extraction-capillary electrophoresis (SPE-CE) has been developed. A single capillary was employed featuring a short monolithic SPE column created inside the capillary via photo-initiated, free-radical polymerisation of 3-sulfopropyl methacrylate and butyl methacrylate monomers. A weak electrolyte of dilute H2SO4, pH 2.9, was found to promote adsorption of the amino acids onto the SPE column. Elution of the amino acids was achieved using a dual solvation/ion-exchange transient boundary mobilised via EOF by using a strong electrolyte containing 62.5mM ethylenediamine, pH 2.9 with H2SO4 and 40% (v/v) acetonitrile. Using these two electrolytes, tryptophan was adsorbed onto the SPE column in weak electrolyte and eluted via a frontal electroelution mechanism in the strong electrolyte. Injections up to 20 min, corresponding to over 14 column volumes (or 1400% of the capillary volume) of sample provided quantitative extraction of tryptophan from the weak electrolyte and were eluted without any loss in efficiency. This represents a practical increase of approximately 300-fold when compared to a typical hydrodynamic injection occupying 5% of the capillary volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a frit-free SPE-based in-column preconcentration system for capillary electrophoresis.

An in-capillary sample preconcentration strategy based on solid phase extraction (SPE) technology coupled with capillary electrophoresis (CE) has been developed taking advantage of both techniques (SPE and CE). An in-line frit-free preconcentration device for capillary electrophoresis containing MCX beads, obtained from the corresponding Waters OASIS cartridges, was prepared. The retention of t...

متن کامل

Development of a New Microextraction Fiber Combined to On-Line Sample Stacking Capillary Electrophoresis UV Detection for Acidic Drugs Determination in Real Water Samples

A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromato...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

1 2 3 4 In - line preconcentration capillary zone electrophoresis for the analysis of haloacetic acids in 5 water

27 Two in-line enrichment procedures (large volume sample stacking (LVSS) and field 28 amplified sample injection (FASI)) have been evaluated for the capillary zone electrophoresis 29 (CZE) analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal 30 polarity by using 20 mM acetic acid-ammonium acetate (pH 5.5) containing 20% acetonitrile as 31 BGE was required. For ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytica chimica acta

دوره 556 1  شماره 

صفحات  -

تاریخ انتشار 2006