Peak inspiratory flow and inspiratory vital capacity of patients with asthma measured with and without a new dry-powder inhaler device (Turbuhaler).

نویسندگان

  • T Engel
  • J H Heinig
  • F Madsen
  • K Nikander
چکیده

In 101 asthmatic adults with varying degrees of bronchial obstruction, lung function tests including peak inspiratory flow (PIF), inspiratory vital capacity (IVC), peak expiratory flow (PEF), forced vital capacity (FVC), and forced expiratory volume in one second (FEV1) measurements were made. Significant correlations between inspiratory and expiratory volumes were found. In most patients, PIF was less reduced than the expiratory parameters of pulmonary function. When inhalation was performed through the new multi-dose, dry-powder inhalation device, Turbuhaler (PIF-TBH), it was significantly lower than PIF measured without Turbuhaler. In previous studies, PIF-TBH of 30 l.min-1 or more has proven sufficient to produce a therapeutic dose of terbutaline, and to produce significant bronchodilatation. Of 101 asthmatics in the present study, only four had PIF-TBH of less than 30 l.min-1. Although no parameters of spirometry could accurately predict PIF-TBH, there was a tendency for patients with severely impaired ventilatory capacity to produce lower PIF-TBH than patients with normal or near-normal ventilatory capacity. If patients with severely impaired ventilatory capacity are to receive inhalation therapy through Turbuhaler, either PIF or PIF-TBH should be measured, or the effect should be carefully monitored.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak inspiratory flow through Turbuhaler in acute asthma.

Efficient use of dry powder inhalers, such as Turbuhaler, is dependent on the generation of adequate inspiratory flow. It is not clear whether patients with acute asthma are able to generate adequate flow. Peak inspiratory flow (PIF) was measured through an empty Turbuhaler, and without this device, in 99 adults presenting to hospital with acute exacerbations of asthma. Where possible, patients...

متن کامل

Inspiratory flow rates at different levels of resistance in elderly COPD patients.

Dry powder inhalers (DPIs) are increasingly replacing metered dose inhalers in elderly chronic obstructive pulmonary disease (COPD) patients. However, most DPIs are dependent on inspiratory flow, which is compromised by the ageing process itself. Using the in-check dial method, the present study compared peak inspiratory flow (PIF) rates in 26 elderly COPD patients and 14 matched control subjec...

متن کامل

[Measurement of inspiratory flow for the selection of the inhalation treatment device for asthma and COPD].

AIM To assess the proportion of patients with asthma or chronic obstructive pulmonary disease (COPD) with significant bronchoobstruction who do not have inspiratory flows necessary for the adequate use of dry powder inhaler (DPI) devices Diskus and Turbuhaler. PATIENTS AND METHODS multicentre cross-sectional study that included 400 patients with asthma or COPD (with FEV1 < 60%) aged 5-91 year...

متن کامل

Peak inspiratory flow rate and slope of the inhalation profiles in dry powder inhalers.

Aerosol delivery depends on device design and inhalation technique. In vitro device evaluations have shown that the emitted dose and fine particle mass of dry powder inhalers (DPIs) increase at high peak inspiratory flow rates (PIFR). Since the PIFR is mostly achieved after the release of the powder, slope of the pressure profile is also described as an important determinant. The aim of the pre...

متن کامل

Peak inspiratory flow rate measurement by using In-Check DIAL for the different inhaler devices in elderly with obstructive airway diseases

BACKGROUND Inhaler device technique is a common cause of treatment failure in patients with asthma and chronic obstructive pulmonary disease. Dry powder inhaler (DPI) requires optimal peak inspiratory flow rate (PIFR) for drug delivery. Low PIFR generation is common in the elderly. Patient lung function and intrinsic inhaler resistance are factors for determining generated PIFR and drug deliver...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 3 9  شماره 

صفحات  -

تاریخ انتشار 1990