Comparative assessment of methods for estimating tumor volume and standardized uptake value in (18)F-FDG PET.
نویسندگان
چکیده
UNLABELLED In (18)F-FDG PET, tumors are often characterized by their metabolically active volume and standardized uptake value (SUV). However, many approaches have been proposed to estimate tumor volume and SUV from (18)F-FDG PET images, none of them being widely agreed upon. We assessed the accuracy and robustness of 5 methods for tumor volume estimates and of 10 methods for SUV estimates in a large variety of configurations. METHODS PET acquisitions of an anthropomorphic phantom containing 17 spheres (volumes between 0.43 and 97 mL, sphere-to-surrounding-activity concentration ratios between 2 and 68) were used. Forty-one nonspheric tumors (volumes between 0.6 and 92 mL, SUV of 2, 4, and 8) were also simulated and inserted in a real patient (18)F-FDG PET scan. Four threshold-based methods (including one, T(bgd), accounting for background activity) and a model-based method (Fit) described in the literature were used for tumor volume measurements. The mean SUV in the resulting volumes were calculated, without and with partial-volume effect (PVE) correction, as well as the maximum SUV (SUV(max)). The parameters involved in the tumor segmentation and SUV estimation methods were optimized using 3 approaches, corresponding to getting the best of each method or testing each method in more realistic situations in which the parameters cannot be perfectly optimized. RESULTS In the phantom and simulated data, the T(bgd) and Fit methods yielded the most accurate volume estimates, with mean errors of 2% +/- 11% and -8% +/- 21% in the most realistic situations. Considering the simulated data, all SUV not corrected for PVE had a mean bias between -31% and -46%, much larger than the bias observed with SUV(max) (-11% +/- 23%) or with the PVE-corrected SUV based on T(bgd) and Fit (-2% +/- 10% and 3% +/- 24%). CONCLUSION The method used to estimate tumor volume and SUV greatly affects the reliability of the estimates. The T(bgd) and Fit methods yielded low errors in volume estimates in a broad range of situations. The PVE-corrected SUV based on T(bgd) and Fit were more accurate and reproducible than SUV(max).
منابع مشابه
Prognostic value of various metabolic parameters on pre-treatment 18-F-FDG PET/CT in patients with stage I-III non-small cell lung cancer
Background: the aim of this study was to investigate the prognostic value of 18Fluorine-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) parameters in both overall survival and progression-free survival in Stage I-III non-small cell lung cancer (NSCLC). Materials and Methods: In this retrospective study, 267 patients who were diagnosed as Stage I-III non-smal...
متن کامل18F-FDG PET/CT of advanced gastric carcinoma and association of HER2 expression with standardized uptake value
Objective(s): Expression of HER2 in gastric carcinoma has direct prognostic and therapeutic implications in patient management. The aim of this study is to determine whether a relationship exists between standardized uptake value (SUV) and expression of HER2 in advanced gastric carcinoma. Methods: We analyzed the 18F-FDG PET/CT results of 109 patients that underwent gastrectomy for advanced gas...
متن کاملBackground-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملFactors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging
Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...
متن کاملPrognostic ability of 18F-FDG PET/CT in the assessment of colorectal liver metastases.
UNLABELLED Modern multidisciplinary therapy for colorectal liver metastases (CRLM) is associated with significant morbidity and must be adapted to the patient's relative risk. The tools currently available to risk-stratify patients are limited. This study assessed the prognostic utility of metabolic measurements derived from(18)F-FDG PET compared with previously proposed prognostic scoring syst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 51 2 شماره
صفحات -
تاریخ انتشار 2010