Holding Strength of Suture: An Experimental Study Using Porcine Kidney
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES The search for the perfect suture is going on and has resulted in the introduction of many different suture types into the market. The purpose of this study is to investigate the holding strength (HS) of different sutures in the renal parenchyma in an experimental study on pig kidneys. METHODS The HS that caused sliding of the suture was investigated in 5 adult porcine kidneys with 7 suture variants. HS-caused tearing of the kidney was investigated with 3 suture types on 5 kidneys. The third investigation, performed on 5 porcine kidneys, was a comparison between 2-0 Vicryl sutures with a Hem-o-lok clip and 2-0 V-Loc sutures with 1 knot. The Friedman test was used to compare the groups. Post hoc analysis was performed with the Wilcoxon signed ranks test (Bonferroni corrected). RESULTS For HS causing sliding of the suture, the mean HSs of the tested sutures were as follows: 2-0 Vicryl with 1 Hem-o-lok clip, 3.26 ± 0.55 N; 2-0 Vicryl with 2 Hem-o-lok clips, 4.1 ± 0.46 N; 2-0 V-Loc, 2.52 ± 0.63 N; 4-0 V-Loc, 1.62 ± 0.17 N; 0 Quill, 0.48 ± 0.16 N; 2-0 Vicryl with 1 Hem-o-lok clip (halfway), 3.62 ± 0.66 N; and 2-0 V-Loc (halfway), 1.02 ± 0.40 N. For HS causing tearing of the kidney, the mean value of 2-way 2-0 Vicryl (Hem-o-lok in the middle) was 13.28 ± 1.38 N, 2-0 2-way Vicryl (Hem-o-lok at the end) was 5.86 ± 0.75 N, and 2-way 2-0 V-Loc was 3.98 ± 1.60 N. For the third group, the difference between the 2 suture variants was not statistically significant. CONCLUSION Our study revealed that 2-0 Vicryl (polyglactin 910) sutures with 2 Hem-o-lok clips had the maximum HS in renal parenchyma when compared with other sutures.
منابع مشابه
Biomechanical evaluation of suture-holding properties of native and tissue-engineered articular cartilage.
The purpose of this study was to determine suture-holding properties of tissue-engineered neocartilage relative to native articular cartilage. To this end, suture pull-out strength was quantified for native articular cartilage and for neocartilages possessing various mechanical properties. Suture-holding properties were examined in vitro and in vivo. Neocartilage from bovine chondrocytes was en...
متن کاملComparison of Bioabsorbable Suture Anchor Fixation on the Tibial Side for Anterior Cruciate Ligament Reconstruction Using Free Soft Tissue Graft: Experimental Laboratory Study on Porcine Bone
PURPOSE The use of graft tissue fixation using bioabsorbable interference screws (BISs) in anterior cruciate ligament (ACL) reconstruction offers various advantages, but limited pullout strength. Therefore, additional tibial fixation is essential for aggressive rehabilitation. We hypothesized that additional graft tissue fixation using bioabsorbable suture anchors (BSA) would provide sufficient...
متن کاملTendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep
BACKGROUND Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In orde...
متن کاملComparison of tensile strength of fibrin glue and suture in microflap closure.
OBJECTIVES/HYPOTHESIS Suture closure and fibrin glue placement have been advocated as alternatives to healing by secondary intention. The aim of this study was to examine the tensile strength of these microflap closure techniques. STUDY DESIGN Basic research. METHODS Three pairs of excised bovine true vocal folds underwent microflap creation and closure by either single 6-0 polyglactin sutu...
متن کاملNovel flat and wide meniscal repair material improves the ultimate load of knot breakage in a porcine trans-capsular meniscal repair model
BACKGROUND In the meniscal repair procedures, a high ultimate load capacity and low cyclic creep at the repair site are favorable and lead to good biological incorporation of the tear site after surgery. Previous biomechanical tensile tests of the meniscal sutures have identified the suture knot as the weakest point. We hypothesized that the strength of a suture knot depends on the suture shape...
متن کامل