Medium-term follow up of residual shunting and potential complications after transcatheter occlusion of the ductus arteriosus.

نویسندگان

  • A G Magee
  • O Stumper
  • J E Burns
  • M J Godman
چکیده

OBJECTIVES To determine the causes and outcome of residual shunting after transcatheter occlusion of persistent ductus arteriosus with the Rashkind double umbrella occluder, and to determine the potential of the device to produce obstruction to flow in the aorta and left pulmonary artery. DESIGN Angiographic examination of morphology of ductus followed by prospective clinical and ultrasound evaluation (including cross sectional imaging, colour flow mapping, and pulse wave Doppler) of all patients undergoing occlusion of persistent ductus arteriosus between October 1987 and July 1992. PATIENTS 140 patients with ages between 0.5 and 78 (median 3.8) years and weights between 6.8 and 74 (median 13.8) kg. INTERVENTIONS Attempted implantation of the Rashkind double umbrella ductus occluder under angiographic control through a transvenous (n = 136) or transarterial (n = 4) approach. MAIN OUTCOME MEASURES Successful occlusion of ductus; frequency, pattern, and prognosis of residual shunts; Doppler velocities in left pulmonary artery and aorta; volume loading of the left heart. RESULTS Including reocclusions the overall rate of successful occlusion was 96%. A total of six devices embolised at the time of operation (4.3%) with no sequelae. There were no anatomical factors that predicted a poor outcome, but suboptimal positioning of the device led to a significantly higher incidence of residual shunts (p < 0.001). Colour flow mapping correctly identified shunts that were unlikely to close spontaneously (n = 9) and to date seven have undergone successful closure with a second device. Encroachment of device legs produced statistically (p < 0.001) but not clinically significant increases in left pulmonary artery Doppler velocities that diminished with time. CONCLUSIONS Transcatheter occlusion provides a safe and effective means of closing a persistent ductus arteriosus. Doppler colour flow mapping is necessary for follow up and shows those ducts requiring reocclusion. The device did not produce significant disturbance to flow in the pulmonary arteries or aorta.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter occlusion of the persistently patent ductus arteriosus. Forty-month follow-up and prevalence of residual shunting.

BACKGROUND Percutaneous closure of the persistently patent ductus arteriosus with the Rashkind prosthesis is an established effective therapeutic modality, although some patients are left with residual shunting. To evaluate this, a retrospective study of the prevalence of persistent shunting over a 40-month period in the first 190 patients was undertaken. METHODS AND RESULTS All patients (mal...

متن کامل

Two-dimensional echocardiographic and color flow Doppler evaluation of ductal occlusion with the Rashkind prosthesis.

To evaluate the results of ductal occlusion with the Rashkind prosthesis, 78 children (group 1, 19 boys and 59 girls; mean age at occlusion, 4.5 +/- 4.0 years) with isolated patent ductus arteriosus (n = 73) or in association with other lesions (n = 5) were evaluated by pulsed and color flow Doppler 9 +/- 7 months (range, 2-26 months) after occlusion. Thirty children who had undergone patent du...

متن کامل

Transcatheter occlusion of patent ductus arteriosus with Gianturco coils.

BACKGROUND Transcatheter occlusion with Gianturco coils has been attempted in a small number of patients with tiny (< or = 1.5-mm diameter) patent ductus arteriosus, and preliminary results have been encouraging. The present study extends this method to larger ductus sizes and makes recommendations for proper coil size selection. METHODS AND RESULTS Coil occlusion was attempted in 24 consecut...

متن کامل

Transcatheter Closure of a Residual Patent Ductus Arteriosus After Surgical Ligation in Children

BACKGROUND AND OBJECTIVES To assess the safety and efficacy of transcatheter closure of residual ductal flow after initial surgical ligation of the arterial duct. SUBJECTS AND METHODS Between June 2005 and December 2009, transcatheter occlusion of residual postsurgical ductus arteriosus was performed in six children. RESULTS The mean patient age was 10±5.5 years; mean post-procedural time s...

متن کامل

Reopening after successful coil occlusion for patent ductus arteriosus.

OBJECTIVES This study was performed to determine the frequency of patent ductus arteriosus (PDA) reopening and the factors that may predict reopening after successful coil occlusion. BACKGROUND Transcatheter coil occlusion is a widely used and accepted method to close a PDA. After documented successful coil occlusion, we found PDAs that reopened. We hypothesized that specific factors are invo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 1994