Biomechanical properties of anterior thoracolumbar multisegmental fixation: an analysis of construct stiffness and screw-rod strain.
نویسندگان
چکیده
STUDY DESIGN Three types of anterior thoracolumbar multisegmental fixation were biomechanically compared in construct stiffness and rod-screw strain. OBJECTIVES To investigate the effects of rod diameter and rod number on construct stiffness and rod-screw strain in anterior thoracolumbar multisegmental instrumentation. SUMMARY OF BACKGROUND DATA No studies have been undertaken to investigate the biomechanical effects of rod diameter and rod number in thoracolumbar anterior instrumentation. METHODS Ten fresh-frozen calf spines (T13-L5) were used. After intact analysis, a total discectomy and transection of the ALL and PLL were performed at L1-L2, L2-L3, and L3-L4 with intervertebral reconstruction using carbon fiber cages. Three types of anterior fixation were then performed at L1-L4: 1) 4.75-mm diameter single-rod, 2) 4.75-mm dual-rod, and 3) 6.35-mm single-rod systems. Single screws at each vertebra were used for single-rod and two screws for dual-rod fixation. These systems share the same basic design except rod diameter. Nondestructive biomechanical testing was performed and included compression, torsion, flexion-extension, and lateral bending. Construct stiffness and rod-screw strain of the three reconstructions were compared. RESULTS The 6.35-mm single-rod fixation significantly improved construct stiffness compared with the 4.75-mm single rod fixation only under torsion (P < 0.05). The 4. 75-mm dual rod construct resulted in significantly higher stiffness than did both single-rod fixations (P < 0.05), except under compression. No statistical differences were observed in rod-screw strain between the two types of single rods, whereas dual-rod reconstruction exhibited less rod-screw strain (P < 0.05). CONCLUSIONS For single-rod fixation, increased rod diameter neither markedly improved construct stiffness nor affected rod-screw strain, indicating the limitations of a single-rod system. In thoracolumbar anterior multisegmental instrumentation, the dual-rod fixation provides higher construct stiffness and less rod-screw strain compared with single-rod fixation.
منابع مشابه
Biomechanical characteristics of fixation methods for floating pubic symphysis
BACKGROUND Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The g...
متن کاملBiomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support
BACKGROUND Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respecti...
متن کاملIn vitro biomechanical evaluation of four fixation techniques for distractive–flexion injury stage 3 of the cervical spine
PURPOSE Anterior plate fixation has been reported to provide satisfactory results in cervical spine distractive flexion (DF) injuries stages 1 and 2, but will result in a substantial failure rate in more unstable stage 3 and above. The aim of this investigation was to determine the biomechanical properties of different fixation techniques in a DF-3 injury model where all structures responsible ...
متن کاملBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...
متن کاملBiomechanical Evaluation of Unilateral Versus Bilateral C1 Lateral Mass-C2 Intralaminar Fixation
STUDY DESIGN Biomechanical, cadaveric study. OBJECTIVES To compare the relative stiffness of unilateral C1 lateral mass-C2 intralaminar fixation to intact specimens and bilateral C1 lateral mass-C2 intralaminar constructs. METHODS The biomechanical integrity of a unilateral C1 lateral mass-C2 intralaminar screw construct was compared to intact specimens and bilateral C1 lateral mass-C2 intr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 25 18 شماره
صفحات -
تاریخ انتشار 2000