Mechanism of failure eleven years following a Buechel Pappas hip resurfacing.

نویسندگان

  • Ajay Malviya
  • Steven Lobaz
  • James Holland
چکیده

Hip resurfacing is gaining popularity as an acceptable treatment option for young active patients with hip osteoarthritis. The Buechel-Pappas hip resurfacing system has a titanium alloy femoral and acetabular component with a polyethylene liner. The titanium nitride coating of the femoral component has been shown to have a very low wear rate during in vivo laboratory studies. Although it has been on the marketplace since 1989, we could find no followup results in the literature. We report a rare case of Buechel-Pappas hip resurfacing which presented with catastrophic failure at 11 years follow-up. The polyethylene liner was worn through, and there was severe metallosis with extensive titanium debris. The head of the femur was however viable, suggesting that the failure of the procedure was due to the bearing surface.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two- to 12-year evaluation of cementless Buechel-Pappas total hip arthroplasty.

A unique, straight-stemmed, proximally porous-coated, modular hip arthroplasty system, coated with thin-film (5- to 9-microm), titanium-nitride ceramic, was used clinically in 130 hip arthroplasties in 117 patients who were followed over a 2- to 12-year interval (mean, 6.45 years). Harris Hip Scores demonstrated 82.3% excellent, 15.4% good, 2.3% fair, and 0% poor results. Thigh pain that limite...

متن کامل

Efficacy of hip resurfacing arthroplasty: 6 year results from an international multisurgeon prospective cohort study.

Metal-on-metal hip resurfacing is undertaken worldwide. This procedure helps preserve femoral bone stock and allows patients to return to high activity sports. Most outcome studies are individual surgeon case series from single centers where the results and outcomes are evaluated by the same surgeon. One method of increasing the external validity of a follow-up study is to have a multi-centre s...

متن کامل

Metal-on-metal hip resurfacing with an uncemented femoral component. A seven-year follow-up study.

BACKGROUND Metal-on-metal hip resurfacing with hybrid fixation has been introduced as an alternative to standard total hip arthroplasty, especially for young and active patients. There are few studies in the literature on the midterm results of cementless femoral side resurfacing. The purpose of this study was to present our seven-year clinical results of a series of twenty cementless metal-on-...

متن کامل

Canadian academic experience with metal-on-metal hip resurfacing.

The current depth and breadth of experience in hip resurfacing in Canadian academic centers is not well known. This study endeavors to increase awareness of the prevalence of programs and current experience in a select number of representative teaching centers by examining the learning curve of high-volume surgeons. A questionnaire was sent to all academic centers in Canada to identify the volu...

متن کامل

Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.

We sought to establish the incidence of joint failure secondary to adverse reaction to metal debris (ARMD) following metal-on-metal hip resurfacing in a large, three surgeon, multicentre study involving 4226 hips with a follow-up of 10 to 142 months. Three implants were studied: the Articular Surface Replacement; the Birmingham Hip Resurfacing; and the Conserve Plus. Retrieved implants underwen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 73 6  شماره 

صفحات  -

تاریخ انتشار 2007