Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study.
نویسندگان
چکیده
OBJECTIVES Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI in patients with THA and 2) to compare DCE-MRI in patients with MoM bearings with metal-on-polyethylene (MoP) bearings, hypothesising that the perfusion index Ktrans in hips with MoM THA is higher than in hips with MoP THA. METHODS In this pilot study, 16 patients with primary THA were recruited (eight MoM, eight MoP). DCE-MRI of the hip was performed at 1.5 Tesla (T). For each patient, Ktrans was computed voxel-by-voxel in all tissue lateral to the bladder. The mean Ktrans for all voxels was then calculated. These values were compared with respect to implant type and gender, and further correlated with clinical parameters. RESULTS There was no significant difference between the two bearing types with both genders combined. However, dividing patients by THA bearing and gender, women with MoM bearings had the highest Ktrans values, exceeding those of women with MoP bearings (0.067 min(-1) versus 0.053 min(-1); p-value < 0.05) and men with MoM bearings (0.067 min(-1) versus 0.034 min(-1); p-value < 0.001). Considering only the men, patients with MoM bearings had lower Ktrans than those with MoP bearings (0.034 min(-1) versus 0.046 min(-1); p < 0.05). CONCLUSION DCE-MRI is feasible to perform in tissues surrounding THA. Females with MoM THA show high Ktrans values in DCE-MRI, suggesting altered tissue perfusion kinematics which may reflect relatively greater inflammation.Cite this article: Dr P. E. Beaule. Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot stud. Bone Joint Res 2016;5:73-79. DOI: 10.1302/2046-3758.53.2000572.
منابع مشابه
No superiority of cemented metal-on- metal over metal-on-polyethylene total hip arthroplasty in a randomized trial at 10-year follow-up
In a randomized controlled trial, 102 cemented Stanmore 28-mm metal-on-metal total hip arthroplasties (THAs) were compared to 98 metal-on-polyethylene THAs in 195 patients. At a mean follow-up of 10 years, 11 patients (11 hips) were lost to followup, 53 patients (55 hips) died, and 6 patients (6 hips) underwent revision. Average age of the surviving patients was 79 years. Harris Hip Scores and ...
متن کاملDistributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients.
BACKGROUND The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons....
متن کاملCementless Total Hip Arthroplasty Involving Trochanteric Osteotomy without Subtrochanteric Shortening for High Hip Dislocation
BACKGROUND Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contem...
متن کاملSilent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty
BACKGROUND AND PURPOSE Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty. METHODS We studied the early clinical results and results of routine metal artifact-re...
متن کاملEarly osteolysis following second-generation metal-on-metal hip replacement.
BACKGROUND Total hip arthroplasty with use of metal-on-metal bearings has been reintroduced as an alternative to the use of metal-on-polyethylene bearings because of theoretical advantages such as reduced wear and a lower prevalence of osteolysis. However, we observed early osteolysis in a cohort of patients who had been managed with second-generation metal-on-metal hip replacements and investi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bone & joint research
دوره 5 3 شماره
صفحات -
تاریخ انتشار 2016