Facilitated anastomosis using a reverse thermo-sensitive polymer for temporary coronary occlusion in off-pump minimally invasive direct coronary artery bypass surgery.

نویسندگان

  • Ardawan Julian Rastan
  • Thilo Noack
  • Sreekumar Subramanian
  • Alpen Nacar
  • David Holzhey
  • Volkmar Falk
  • Friedrich Wilhelm Mohr
چکیده

To evaluate the safety and efficacy of a novel, reverse thermo-sensitive polymer (LeGoo™) for its ability to provide temporary coronary occlusion and hemostasis during minimally invasive direct coronary artery bypass (MIDCAB) surgery. Between January 2009 and March 2009, 20 consecutive MIDCAB patients were studied. Ten patients received a conventional MIDCAB procedure using proximal vessel loops and CO2 blower (control group). The following 10 patients were operated by an otherwise identical procedure, except that intracoronary administration of LeGoo™ was used instead of vessel snares (LeGoo™ group). Left internal mammary artery (LIMA) bypass flow, peri- and postoperative events and perioperative creatinine kinase-MB fraction (CK-MB) release were prospectively analyzed. CO2-blower use was required in three of 10 of the LeGoo™ patients. Procedural time was identical, with a trend of shorter anastomosis time in the LeGoo™ group (12.3 vs. 10.7 min, P=0.11). LIMA-LAD flow was also not different (control 35.8 vs. LeGoo™ 42.5 ml/min, P=0.541). CK-MB values were not statistically different on postoperative days 1 and 2. However, the level of CK-MB 4 h postoperatively was lower in LeGoo™ patients (18.3±6.1 vs. 13.2±2.9 U/l, P=0.006). No major adverse cerebral or cardiovascular event occurred postoperatively and during follow-up of 317±21 days. Using LeGoo™ to achieve temporary coronary artery occlusion is easier to work with during MIDCAB due to the absence of vessel snares and less need of blowing to eliminate blood from the operative field. There were no negative postoperative events associated with the use of LeGoo™.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vascular connector devices increase the availability of minimally invasive cardiac surgery to ischemic heart patients

The revival of off-pump cardiac surgery and the exploration of less invasive techniques for coronary artery bypass grafting, have lead to an increasing technical difficulty, as compared to conventional surgery using cardiopulmonary bypass. The moving target vessel in off-pump coronary artery bypass surgery, as well as the increasingly limited space in minimally invasive cardiac surgery were not...

متن کامل

Angiographic results after minimally invasive coronary bypass grafting using the minimally invasive direct coronary bypass grafting (MIDCAB) approach.

OBJECTIVE The aim of the study was to evaluate the early and mid-term angiographic results after minimally invasive coronary bypass grafting using an 'off-pump' technique via a lateral minithoracotomy. METHODS In 221 out of 271 patients (81.5%) who underwent minimally invasive direct coronary bypass grafting (MIDCAB) the quality of the internal thoracic artery (ITA)-graft and the anastomosis ...

متن کامل

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model

To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser c...

متن کامل

Minimally invasive coronary artery bypass grafting without cardiopulmonary bypass: early experience and follow-up.

BACKGROUND There is renewed interest in coronary artery bypass grafting without cardiopulmonary bypass using the anterolateral minithoracotomy approach. We evaluated 209 patients who underwent minimally invasive direct coronary artery bypass grafting using an anterolateral minithoracotomy. The anastomosis was performed under direct vision on the beating heart without using cardiopulmonary bypas...

متن کامل

Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study

Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG.  Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 11 5  شماره 

صفحات  -

تاریخ انتشار 2010