Evaluation of enzyme immunoassay, radioassay, and radioimmunoassay of serum methotrexate, as compared with liquid chromatography.
نویسندگان
چکیده
We evaluated three commonly used clinical methods for measuring serum methotrexate: enzyme immunoassay (EMIT), radioassay, and radioimmunoassay. Because potentially interfering compounds can be resolved by liquid chromatography, this method was selected as the comparison method. Patients' serum samples, taken during 24 h after 6-h high-dose infusions, contained methotrexate in concentrations ranging from 10(-7) to 10(-4) mol/L. Chromatograms revealed substantial amounts of 7-hydroxymethotrexate in all samples, actually exceeding methotrexate by 12 and 24 h. Nevertheless, analysis of variance revealed no significant differences in results by any of the four methods, nor did results by the three test methods differ significantly after being adjusted by analysis of covariance with liquid chromatography as the covariate. Evidently any of the four techniques is suitable for monitoring serum methotrexate for 24 h after high-dose therapy.
منابع مشابه
Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay.
Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoassay, enzyme immunoassay, and liquid chromatography. The essay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatograp...
متن کاملPlasma methotrexate as determined by liquid chromatography, enzyme-inhibition assay, and radioimmunoassay after high-dose infusion.
Three techniques for measuring methotrexate show various cross reactivities with methotrexate-related compounds: "high-pressure" liquid chromatography, by principle, is virtually specific for methotrexate; the enzyme-inhibition assay quantitates methotrexate, methotrexate diglutamate, and methotrexate triglutamate equally well, but has a 10% cross reactivity with 4-amino-4-deoxy-N10-methylptero...
متن کاملEnzyme immunoassay and gas--liquid chromatography compared for determination of lidocaine in serum.
Lidocaine, an anti-arrhythmic drug, was quantitated in serum by a commercially supplied enzyme immunoassay procedure. Replicate analyses of serum controls resulted in a within-assay coefficient of variation of less than 5.0 and a between-assay coefficient of variation of less than 6.5. Regression analysis of 87 serum samples analyzed by this technique (y) and by gas-liquid chromatography (x) g...
متن کاملDetermination of methotrexate in serum by a rapid, fully mechanized enzyme immunoassay (EMIT).
A homogeneous enzyme immunoassay for the determination of methotrexate in serum (EMIT, Syva Corp.) was fully mechanized by the use of an Eppendorf analyzer 5010. Coefficients of variation from day to day were in the range 2--16%. A comparison of the results obtained by EMIT and a radioimmunoassay (Methotrexate 125 I Radioimmunoassay Kit, Diagnostic Biochemistry Inc.) in a series of 50 samples f...
متن کاملRadioimmunoassay, enzyme immunoassay, spectrophotometry, and gas-liquid chromatography compared for determination of phenobarbital and diphenylhydantoin.
Sera from epileptic patients were assayed for phenobarbital and diphenylhydantoin by four different analytical procedures. Quantitative results obtained by radioimmunoassay (I) and enzyme immunoassay (II) were compared to each other and to the results obtained on aliquots of the same sample by gas-liquid chromatography (III) and ultraviolet spectrophotometry (IV). For phenobarbital the correlat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 26 13 شماره
صفحات -
تاریخ انتشار 1980