Monitoring Hepatocyte Dysfunction and Biliary Complication After Liver Transplantation Using Quantitative Hepatobiliary Scintigraphy

نویسندگان

  • Si-Juan Zou
  • Dong Chen
  • Yan-Zhao Li
  • Dun-Feng Du
  • Zhi-Shui Chen
  • Xiao-Hua Zhu
چکیده

The significance of hepatobiliary scintigraphy (HBS) for hepatic graft function assessment was established mostly on retrospective studies and was not widely recognized due to the lack of quantitative data and variation in accuracy. This prospective study was performed to investigate the effectiveness of quantitative HBS for assessing hepatocyte dysfunction and biliary complication in liver transplant recipients.In 57 recipients who had undergone orthotopic liver transplantation, a total of 67 dynamic Tc-EHIDA scans were performed and quantitative parameters including the hepatocyte extraction fraction (HEF), time to maximum hepatic radioactivity (Tmax), and time for peak activity to decrease by 50% (T1/2) were calculated. The scintigraphic results based on the 3 parameters were compared against the final diagnosis. A ROC curve analysis was carried out to identify the cutoff value of Tmax for diagnosis of biliary stricture. Correlation between the parameters of postoperative HBS and conventional biochemical liver function indices were also analyzed.Quantitative Tc-EHIDA HBS had an overall sensitivity of 94.12% (16/17), specificity of 93.33% (42/45), and diagnostic accuracy of 93.55% (58/62) for detecting hepatocyte dysfunction and biliary complication in liver transplant recipients. The recommended cutoff value of Tmax for diagnosis of post-transplant biliary stricture was set at 15.75 min with a sensitivity of 100.0% and a specificity of 94.0%. The scintigraphic parameters (HEF, Tmax) were statistically significantly associated with the conventional liver function parameters.Quantitative Tc-EHIDA HBS offers a noninvasive imaging modality with high sensitivity and specificity to diagnose hepatocyte dysfunction as well as distinguish between patients with or without biliary stricture following liver transplantation. Furthermore, HEF and Tmax values obtained from dynamic HBS show good correlation with conventional liver function parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bile leak detection by radionuclide scintigraphy.

INTRODUCTION Bile leak after liver injury has been reported to be a complication associated with significant mortality. Tc99m-IDA (Tc: Technetium) nuclear scan allows rapid and noninvasive diagnosis of bile leak. OBJECTIVE An accidental case was referred for the detection of suspicious bile leak. METHODS The ultrasound could not detect any abnormality. Dynamic Hepatobiliary Scintigraphy (DH...

متن کامل

Application of ursodeoxycholic acid in hepatobiliary scintigraphy for neonatal hyperbilirubinemia: Comparison with phenobarbital

  Introduction: Early differentiation of biliary atresia from neonatal hepatitis is of utmost importance, since on time surgery of biliary atresia significantly improves the outcome. Hepatobiliary scintigraphy is an integral part of diagnosis work-up of these patients; however its specificity for diagnosis of biliary atresia is suboptimal. In this study we evaluated t...

متن کامل

Potential Pitfalls on the 99mTc-Mebrofenin Hepatobiliary Scintigraphy in a Patient with Biliary Atresia Splenic Malformation Syndrome

Biliary atresia (BA) is an obliterative cholangiopathy affecting 1:10.000-14.000 of newborns. Infants with Biliary Atresia Splenic Malformation syndrome (BASM) are a subgroup of BA patients with additional congenital anomalies. Untreated the disease will result in fatal liver failure within the first years of life. Kasai portoenterostomy restores bile flow and delay the progressive liver damage...

متن کامل

Short and Long Term Complications after Pediatric Liver Transplantation: A Review and Literature

Background: Pediatric liver transplant is a complex surgical procedure. Pediatric liver transplantation has evolved over the last two decades into an effective and widely accepted therapy for infants and children. The aim of our report is to review the current state of knowledge and explore the incidence of complications, the involved pathogens among liver recipients to determine the effective ...

متن کامل

Non-Invasive Diagnostic Methods for Differentiation of Biliary Atresia from Neonatal Hepatitis in Upper Egypt

Background Cholestatic jaundice in infancy is always pathologic and mainly caused by biliary atresia (BA), and neonatal hepatitis (NH). The early discrimination of both conditions is critical for the outcome of BA. We aimed to assess different non-invasive diagnostic tools in differentiating BA from NH. Materials and Methods Forty infants (25 boys, 15 girls) with cholestatic jaundice and final...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015