On the interpretation of Langmuir probe data inside a spacecraft sheath.
نویسندگان
چکیده
If a Langmuir probe is located inside the sheath of a negatively charged spacecraft, there is a risk that the probe characteristic is modified compared to that of a free probe in the ambient plasma. We have studied this probe-in-spacecraft-sheath problem in the parameter range of a small Langmuir probe (with radius r(LP)≪λ(D)) using a modified version of the orbit motion limited (OML) probe theory. We find that the ambient electron contribution I(e)(U(LP)) to the probe characteristic is suitably analyzed in terms of three regions of applied probe potential U(LP). In region I, where the probe is negatively charged (i.e., U(LP)U(1), there is first a transition region II in applied potential, U(1)<U(LP)<U(2), in which the key factor to determine the shape of I(e)(U(LP)) is a potential minimum U(M) between the probe and the ambient plasma. This minimum gives the depth U(pl)-U(M) of a potential barrier that prevents the lowest energy ambient electrons from reaching the probe. For a high enough positive probe potential, in region III, the barrier becomes small. Here, I(e)(U(LP)) again approaches OML theory for a free probe. The boundary U(2) between regions II and III is somewhat arbitrary; we propose a condition on the barrier, U(pl)-U(M)≪k(B)T(e)/e, as the definition of region III. The main findings in this work are qualitative rather than quantitative. The existence of the transition region points to that special care must be taken to extract plasma parameters from measured I(U(LP)) as the probe characteristic is likely to depart from usual OML in crucial respects: (1) the ambient plasma potential U(pl) falls into the transition region, but there is no obvious knee or other feature to identify it, (2) there is in this region no exponential part of I(e)(U(LP)) that can be used to obtain T(e), instead, (3) the probe size is important in determining the curve shape. We have tentatively applied our simplified probe-in-sheath model to real probe data from the Cassini spacecraft, taken in the dense plasma of Saturn's magnetosphere. We propose that our model gives a better description than OML of measured Langmuir probe sweeps in space plasmas where the Langmuir probe is situated within the spacecraft sheath, i.e., for long Debye lengths. The understanding of these probe sweep effects in such regions may improve by self-consistent particle simulations of the spacecraft environment.
منابع مشابه
The spherical segmented Langmuir probe in a flowing thermal plasma: numerical model of the current collection
The segmented Langmuir probe (SLP) has been recently proposed by one of the authors (Lebreton, 2002) as an instrument to derive the bulk velocity of terrestrial or planetary plasmas, in addition to the electron density and temperature that are routinely measured by Langmuir probes. It is part of the scientific payload on the DEMETER microsatellite developed by CNES. The basic concept of this pr...
متن کاملLangmuir probe
Langmuir probes have been installed on satellites and sounding rockets to observe the general characteristics of thermal plasma in the ionosphere for more than five decades. Because of its simplicity and convenience, the Langmuir probe is one of the most frequently installed scientific instruments on spacecraft. While the algorithm to estimate the temperature and number density of thermal elect...
متن کاملTemporal limits of a rapidly swept Langmuir probe
The finite, electrostatically achievable, temporal resolution of plasma properties from a turbulent discharge is limited by an array of effects wherein the theory of Langmuir probes breaks down. Formulations for the particle transit time, sheath formation time, plasma-probe resonance, polarization current, sheath capacitance, stray capacitance, and mutual capacitance effects are all evaluated f...
متن کاملInfluence of O2 and N2 Concentrations on the Characteristics of Plasma in DC Cylindrical Magnetron Discharge by Langmuir Probe
Using the Langmuir probe method, the reactive plasma parameters were studied in different ratios of oxygen and nitrogen concentrations in a DC cylindrical discharge device.The plasma parameters such as plasma potential, electron density and electron temperature wereextracted from the current-voltage characteristic’s curve of Langmuir probe to find the optimum conditions for deposit the oxy...
متن کاملDensity Measurements in Low Pressure, Weakly Magnetized, RF Plasmas: Experimental Verification of the Sheath Expansion Effect
This experimental study shows the validity of Sheridan’s method in determining plasma density in low pressure, weakly magnetized, RF plasmas using ion saturation current data measured by a planar Langmuir probe. The ion density derived from Sheridan’s method which takes into account the sheath expansion around the negatively biased probe tip, presents a good consistency with the electron densit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 81 10 شماره
صفحات -
تاریخ انتشار 2010