Competitive heterogeneous enzyme immunoassay for theophylline by flow-injection analysis with electrochemical detection of p-aminophenol.
نویسندگان
چکیده
A competitive enzyme-linked immunoabsorbent assay based on the flow-injection amperometric detection of p-aminophenol has been investigated with use of the materials and general procedure of a commercial kit for the determination of theophylline in human serum. The antibody is immobilized on glass beads, and the enzyme label is alkaline phosphatase (EC 3.1.3.1). The high currents generated during the electrochemical detection allowed a rapid (35 min) and simple determination of theophylline throughout its therapeutic range (10-20 mg/L) and also in the subtherapeutic range (detection limit of about 80 micrograms/L).
منابع مشابه
Heterogeneous enzyme immunoassay of alpha-fetoprotein in maternal serum by flow-injection amperometric detection of 4-aminophenol.
A sandwich-type heterogeneous enzyme immunoassay with flow-injection analysis for alpha-fetoprotein (AFP) in human serum has been developed. 4-Aminophenol, the product of enzymatic reaction, is detected amperometrically. The interassay CV for this electrochemical enzyme immunoassay was less than 8.2%, with a minimum detection limit for AFP of 0.163 micrograms/L. The calibration curve had a line...
متن کاملLiposome-based flow-injection immunoassay for determining theophylline in serum.
We developed a method for quantitatively determining theophylline in serum, using a heterogeneous immunoassay called flow-injection immunoanalysis. The reaction involves competition between serum theophylline and theophylline-labeled liposomes. Separation occurs on a solid-phase reactor column containing immobilized antibody to theophylline incorporated in a flow-injection system. Subsequent ly...
متن کاملElectrochemical dehydrogenase-based homogeneous assays in whole blood.
An electrochemical method has been developed for determining NADH in whole blood for dehydrogenase-based assays by flow-injection analysis. NADH generated by dehydrogenase is oxidized by an electron-transfer coupling reagent, 2,6-dichloroindophenol (DCIP). The reduced form of DCIP (DCIPH2) is measured amperometrically by flow-injection analysis. Endogenous interferents were inhibited by p-hydro...
متن کاملFlow Immunoassay Based on Sequential Injection Using Microbeads
A flow immunoassay based on a combined technique of the sequential injection with the beads injection using magnetic microbeads immobilized with antigen or antibody is described. A methodology of the present immunoassay based on chemiluminescence and electrochemical detection and its application to the determination of vitelloginin (Vg) and anionic surfactant, linear alkylbenzene sulfonate (LAS...
متن کاملCapillary electrophoresis-based immunoassay for the determination of brevetoxin-B in shellfish using electrochemical detection.
Neurotoxic shellfish poisoning is a significant food-borne disease caused by potent cyclic polyether toxins (brevetoxins) that accumulate in the flesh of shellfish. Here we report a new procedure for brevetoxin analysis by capillary electrophoresis-based immunoassay (CE-IA) with electrochemical (EC) detection. In this method, after the competitive immunoreaction in liquid phase, the horseradish...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 36 4 شماره
صفحات -
تاریخ انتشار 1990