Intraoperative flow measurements in gastroepiploic grafts using pulsed Doppler.

نویسندگان

  • Y Louagie
  • M Buche
  • P Eucher
  • J C Schoevaerdts
چکیده

OBJECTIVE The patency of a pedicled right gastroepiploic artery (RGEA) graft can be compromised by intraoperative twists, kinks or spasms. Therefore, a systematic flow assessment was made in RGEA grafts and was compared with similar measurements made in other types of bypass conduits. METHODS Intraoperative pulsed Doppler flowmeter measurements obtained in a series of 556 consecutive patients undergoing at least one coronary bypass grafting onto the right coronary system were studied. Eighty-five RGEA grafts were compared with 1427 bypass grafts implanted in the same group of patients and consisted of the following conduits: 442 left internal mammary (LIMA), 149 right internal mammary (RIMA), 831 greater saphenous vein (GSV) and five inferior epigastric (EPIG) grafts. Sequential grafts were excluded from the analysis. RESULTS Flow measurements and Doppler waveforms were abnormal and required graft repositioning, and the addition of a distal graft or intragraft papaverine injection (only in GSVs) in 29 cases (2.0% of all grafts). These graft corrections were necessary in 5.9% RGEAs, 3.4% LIMAs, 2.0% RIMAs, and 0.7% GSVs (P < 0.001). The relative risk for graft correction was eight times higher for RGEAs than for GSVs (P = 0.002). Flow increased from 8 +/- 2 to 54 +/- 5 ml/min (P < 0.0001). Flow data were significantly influenced by the type of run-off bed (P < 0.001), the measurements obtained in grafts implanted onto the right coronary artery and the left anterior descending artery being superior. Flows in RGEAs, however, were comparable with values obtained in other grafts implanted onto the same recipient coronary artery. CONCLUSIONS A significantly higher incidence of graft malpositioning caused inadequate flows in RGEAs. However, normal flow values could be restored simply by assigning a better graft orientation under pulsed Doppler flowmeter control. Overall flow capacity of the RGEA did not differ from values obtained in other arterial and venous grafts implanted onto the same recipient arteries.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gastroepiploic artery coronary bypass graft: non-invasive patency evaluation using color and duplex Doppler ultrasonography.

OBJECTIVE Color and duplex Doppler ultrasound and digital subtraction angiography were compared for the evaluation of graft patency of the gastroepiploic artery (GEA). METHODS In 77 observations, ultrasound and digital subtraction angiography were compared. The coronary resistance index (cRI) was defined as the maximal systolic flow velocity minus the maximal diastolic flow velocity, divided ...

متن کامل

Evaluation of gastroepiploic arterial grafts to right coronary artery using transit-time flow measurement.

OBJECTIVES The objective of this study was to analyse the relationship between the intraoperative transit-time flow measurement (TTFM) parameter values and the postoperative angiographic results of gastroepiploic arterial (GEA) grafts to the right coronary artery (RCA). We investigated whether the intraoperative TTFM parameter values are reliable indicators of early patency in GEA grafts to the...

متن کامل

Spleen-preserving distal pancreatectomy with resection of the splenic vessels. Should one rely on the short gastric arteries?

CONTEXT Knowing the collaterals is essential for a spleen-preserving distal pancreatectomy with resection of the splenic vessels. OBJECTIVE To ascertain the sources of the blood supply to the spleen after a spleen-preserving distal pancreatectomy with resection of the splenic vessels. METHODS Perfusion of the cadaveric left gastric and right gastroepiploic arteries with methylene blue after...

متن کامل

Normal Color and Pulsed-Waved Doppler Ultrasonography of Femoral and Axillary Arteries in Dogs

Objective- Obtaining the normal images ofcolor doppler and estimation ofblood flow velocity parametersof femoral and axillary arteries in dog.Design- Descriptive studyAnimals- 7 healthy adult mixed-breed dogs, weighing 14.3 ± 2.8 kg (mean ± SD).Proceudure- Left and right femoral and axillary arteries of hind and forelimbs were evaluated. Colorand spectral doppler images ofthe each artery were o...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 1999