Coded Excitation Methods for Ultrasound Harmonic Imaging
نویسنده
چکیده
Coded excitation methods offer the potential for improving the SNR without increasing the peak transmitted power and without sacrificing resolution. Our study examines the potential application of coded waveforms, specifically FM chirps, in harmonic imaging. Such a system, in which nonlinear echoes from tissue are used to form the image, requires the extraction and compression of the second harmonic portion of the echo signal. Our objective is to obtain the second harmonic using just one transmission, thereby avoiding problems of frame rate reduction and movement artifacts associated with multiple transmission schemes. With the help of an efficient method for predicting the transient nonlinear field from a focused transducer, design issues such as waveform and bandwidth selection, as well as filters for second harmonic extraction and compression are examined. Simulations reveal the presence of axial sidelobes in the compressed echo waveform as the bandwidth of the transmitted chirp is increased. These sidelobes, resulting from the overlap of the fundamental and third harmonic bands with the second harmonic, cannot be removed using conventional Fourier filtering. Alternative filtering techniques which utilize the separation of the harmonic bands of a backscattered chirp in the joint time-frequency domain are suggested.
منابع مشابه
Ultrasound Elasticity Imaging System with Chirp-Coded Excitation for Assessing Biomechanical Properties of Elasticity Phantom
The biomechanical properties of soft tissues vary with pathological phenomenon. Ultrasound elasticity imaging is a noninvasive method used to analyze the local biomechanical properties of soft tissues in clinical diagnosis. However, the echo signal-to-noise ratio (eSNR) is diminished because of the attenuation of ultrasonic energy by soft tissues. Therefore, to improve the quality of elastograp...
متن کاملVitreous image enhancement in an ophthalmic sonographic imaging system using Golay coded excitation.
OBJECTIVE The purpose of this study was to enhance the weak echoes of low reflective vitreous opacities on ophthalmic sonography. METHODS A simulation study on a vitreous enhancement algorithm based on coded excitation was performed, with the analysis of the transmit efficiency and motion effects. On the basis of the simulation results, we have implemented a 10-MHz B-mode experimental sonogra...
متن کاملUltrasound perfusion imaging of the human brain.
BACKGROUND AND PURPOSE Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data to analyze brain tissue perfusion. METHODS In 13 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing ultrasound contrast agent, were injected intravenously, and they produced a strong increase in echo enhancement in the brain parenchyma. The c...
متن کاملAn ultrasound transient elastography system with coded excitation
BACKGROUND Ultrasound transient elastography technology has found its place in elastography because it is safe and easy to operate. However, it's application in deep tissue is limited. The aim of this study is to design an ultrasound transient elastography system with coded excitation to obtain greater detection depth. METHODS The ultrasound transient elastography system requires tissue vibra...
متن کاملBarker-coded excitation in ophthalmological ultrasound imaging.
High-frequency ultrasound is an attractive means to obtain fine-resolution images of biological tissues for ophthalmologic imaging. To solve the tradeoff between axial resolution and detection depth, existing in the conventional single-pulse excitation, this study develops a new method which uses 13-bit Barker-coded excitation and a mismatched filter for high-frequency ophthalmologic imaging. A...