Temperature change rate actuated bubble mixing for homogeneous rehydration of dry pre-stored reagents in centrifugal microfluidics.
نویسندگان
چکیده
In centrifugal microfluidics, dead volumes in valves downstream of mixing chambers can hardly be avoided. These dead volumes are excluded from mixing processes and hence cause a concentration gradient. Here we present a new bubble mixing concept which avoids such dead volumes. The mixing concept employs heating to create a temperature change rate (TCR) induced overpressure in the air volume downstream of mixing chambers. The main feature is an air vent with a high fluidic resistance, representing a low pass filter with respect to pressure changes. Fast temperature increase causes rapid pressure increase in downstream structures pushing the liquid from downstream channels into the mixing chamber. As air further penetrates into the mixing chamber, bubbles form, ascend due to buoyancy and mix the liquid. Slow temperature/pressure changes equilibrate through the high fluidic resistance air vent enabling sequential heating/cooling cycles to repeat the mixing process. After mixing, a complete transfer of the reaction volume into the downstream fluidic structure is possible by a rapid cooling step triggering TCR actuated valving. The new mixing concept is applied to rehydrate reagents for loop-mediated isothermal amplification (LAMP). After mixing, the reaction mix is aliquoted into several reaction chambers for geometric multiplexing. As a measure for mixing efficiency, the mean coefficient of variation (C[combining macron]V[combining macron], n = 4 LabDisks) of the time to positivity (tp) of the LAMP reactions (n = 11 replicates per LabDisk) is taken. The C[combining macron]V[combining macron] of the tp is reduced from 18.5% (when using standard shake mode mixing) to 3.3% (when applying TCR actuated bubble mixing). The bubble mixer has been implemented in a monolithic fashion without the need for any additional actuation besides rotation and temperature control, which are needed anyhow for the assay workflow.
منابع مشابه
Centrifugal microfluidic system for primary amplification and secondary real-time PCR.
Pre-amplification is a basis for numerous polymerase chain reaction (PCR) protocols but bears severe contamination risks due to handling of high-copy DNA samples. Therefore we developed a self-contained centrifugal microfluidic system comprising pre-stored reagents; it enables pre-amplification of specific DNA sequences prior to automated aliquoting and real-time PCR in a modified commercial th...
متن کاملMiniature stick-packaging--an industrial technology for pre-storage and release of reagents in lab-on-a-chip systems.
Stick-packaging of goods in tubular-shaped composite-foil pouches has become a popular technology for food and drug packaging. We miniaturized stick-packaging for use in lab-on-a-chip (LOAC) systems to pre-store and on-demand release the liquid and dry reagents in a volume range of 80-500 μl. An integrated frangible seal enables the pressure-controlled release of reagents and simplifies the lay...
متن کاملOn-card Dry Reagent Storage for Disposable Microfluidic Immunoassays
Point-of-care microfluidic assays for the developing world face uncontrolled storage temperatures that can destroy functionality of on-card reagents. In development of such assays [1], we report a method for dry storage and microfluidic rehydration of immunochemical reagents in a sugar-based matrix on porous media. Using gold-antibody conjugates against the malarial antigen Plasmodium falciparu...
متن کاملAn integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids.
A self-contained, integrated, disposable, sample-to-answer, polycarbonate microfluidic cassette for nucleic acid-based detection of pathogens at the point of care was designed, constructed, and tested. The cassette comprises on-chip sample lysis, nucleic acid isolation, enzymatic amplification (polymerase chain reaction and, when needed, reverse transcription), amplicon labeling, and detection....
متن کاملPre-storage and Release of Purification Reagents for Full “hands-off” Integration of Dna/rna Assays on the Labdisk Platform
For the first time we demonstrate complete integration and pre-storage of all required components for nucleic acid extraction and purification on the centrifugal microfluidic LabDisk platform. On the one hand pre-storage of large volume liquid reagents from 200-–-550 μL is realized in stickpacks, that are stacked to decrease the footprint consumption on the LabDisk and are released automaticall...