Serological cross reaction between legionella and campylobacter in the rapid microagglutination test.

نویسنده

  • T C Boswell
چکیده

AIMS To investigate the serological cross reaction between legionella and campylobacter using the rapid microagglutination test (RMAT). METHODS Serum samples from 49 patients with campylobacter infection were tested for legionella antibodies using the indirect fluorescent antibody test (IFAT) and the RMAT. Serum samples that had positive RMAT titres were retested in the presence of a campylobacter immunosorbent. The specificity of the immunosorbent was evaluated with serum from patients with genuine legionella infection (legionella culture or antigen positive, or both). RESULTS Fourteen (28%) patients with campylobacter infection had positive IFAT titres (> or = 16) and 16 (32%) patients had positive RMAT titres (> or = 8) in one or more serum samples. In addition, serum samples from 11 of 17 patients with campylobacter infection, previously shown to have positive legionella IFAT titres, were also RMAT positive. Sixteen patients had RMAT titres of > or = 32, including seven with titres of > or = 128. RMAT titres from all but one patient were significantly reduced after campylobacter absorption, but serum samples from 48 patients with legionella infection were unaffected. CONCLUSIONS Serological cross reaction between campylobacter and legionella can occur in the legionella RMAT, as well as the IFAT. This cross reaction can be eliminated in most cases by incorporating a campylobacter immunosorbent in the RMAT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rapid microagglutination test for the diagnosis of Legionella pneumophila (serogroup 1) infection.

A rapid microagglutination test has been developed which can be performed in 30 minutes. Ninety-seven percent of 96 patients diagnosed as having Legionella pneumophila (serogroup 1) infection by indirect immunofluorescence were also detected by the rapid microagglutination test.

متن کامل

Evaluation of sensitivity of two serological tests for diagnosing pneumonia caused by Legionella pneumophila serogroup 1.

The sensitivity of an indirect immunofluorescence antibody test (IFAT) and a rapid microagglutination test (RMAT) for the diagnosis of Legionnaires' disease caused by Legionella pneumophila serogroup 1 was evaluated using serum specimens from 119 patients with bacteriologically confirmed infections. The sensitivity of both assays was found to be about 80%. In addition, antibody titres suggestiv...

متن کامل

Rapid Detection of Campylobacter jejuni by Polymerase Chain Reaction and Evaluation of its Sensitivity and Specificity

Introduction: Campylobacter jejuni is one of the most common causes of food poising in humans. Rapid and specific detection of these bacteria has an important role in diagnosis and treatment of infection. The aim of this study was to design a specific PCR for the detection of Campylobacter jejuni. Methods: In this experimental study, oxidoreductase gene from the Campylobacter jejuni was sele...

متن کامل

Cross-reaction to Legionella pneumophila antigen in sera with elevated titers to Pseudomonas pseudomallei.

A significantly greater incidence (P less than 0.005) of Legionella pneumophila microagglutination titers greater than or equal to 32 was found in sera with elevated titers to Pseudomonas pseudomallei as compared with sera with negative titers for P. pseudomallei antibodies. The greater incidence of L. pneumophila titers in these sera suggests that L. pneumophila and P. pseudomallei share an an...

متن کامل

Serological cross-reaction between Legionella spp. and Capnocytophaga ochracea by using latex agglutination test.

Cross-reactivity between Legionella spp. and Capnocytophaga ochracea was noted by latex agglutination tests (Serobact Legionella; Disposable Products, Adelaide, Australia). Four of 11 (36%) C. ochracea isolates agglutinated with latex reagents designed to identify Legionella pneumophila serogroups. C. ochracea isolated on buffered charcoal yeast extract media may give false-positive results in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 49 7  شماره 

صفحات  -

تاریخ انتشار 1996