Abstract. The paper presents a compensating system for the harmonics and the reactive power using active power filter in three-phase and four-wire systems. The conventional active power filters have been designed based on the p-q theory. However, these types of the filter can only compensate for the reactive power for the load and the detection result is not accurate if the three-phase voltage is distorted. To overcome this deficiency, a novel ip-iq algorithm based on the p-q theory is proposed for the control strategy of the active filter. The obtained simulation results show that by using the proposed control strategy, the total harmonics distortion in Matlab/ Simulink can be minimized.
منابع مشابه
A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملComparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کاملFixed-frequency space-vector-modulation control for three-phase four-leg active power filters - Electric Power Applications, IEE Proceedings-
The paper presents a three-dimensional space-vector-modulation scheme for three-phase four-wire active power filters. The focus is on the implementation of a fixed frequency pulse width modulation (PWM) scheme with a minimum number of switch commutations per period and maximum DC bus voltage utilisation. For three-wire applications, space vector modulation is known to provide better utilisation...
متن کاملSeries Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems
This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its...