Physics of pure and non-pure positron emitters for PET: a review and a discussion

نویسندگان

  • Maurizio Conti
  • Lars Eriksson
چکیده

With the increased interest in new PET tracers, gene-targeted therapy, immunoPET, and theranostics, other radioisotopes will be increasingly used in clinical PET scanners, in addition to (18)F. Some of the most interesting radioisotopes with prospective use in the new fields are not pure short-range β(+) emitters but can be associated with gamma emissions in coincidence with the annihilation radiation (prompt gamma), gamma-gamma cascades, intense Bremsstrahlung radiation, high-energy positrons that may escape out of the patient skin, and high-energy gamma rays that result in some e (+)/e (-) pair production. The high level of sophistication in data correction and excellent quantitative accuracy that has been reached for (18)F in recent years can be questioned by these effects. In this work, we review the physics and the scientific literature and evaluate the effect of these additional phenomena on the PET data for each of a series of radioisotopes: (11)C, (13)N, (15)O, (18)F, (64)Cu, (68)Ga, (76)Br, (82)Rb, (86)Y, (89)Zr, (90)Y, and (124)I. In particular, we discuss the present complications arising from the prompt gammas, and we review the scientific literature on prompt gamma correction. For some of the radioisotopes considered in this work, prompt gamma correction is definitely needed to assure acceptable image quality, and several approaches have been proposed in recent years. Bremsstrahlung photons and (176)Lu background were also evaluated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculating Reaction Rate of Positron Emitters During Proton Therapy Which Are Used In Online PET Scan by Monte Carlo Method

Introduction: Nowadays, cancer is one of the most important concerns in human being's societies, more than one-third of people in around the world will get cancer during their lives. Physical dose depth distribution characteristic of protons in a tissue is determined with a low dose in the entrance region, maximum dose in the Bragg region, and rapid decline takes place near the...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Molecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis

Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue.  Methods:PubMed, Scopus and EMBASE were searched for st...

متن کامل

Is there a difference in FDG PET findings of invasive ductal carcinoma of the breast with and without coexisting DCIS?

Objective(s): Studies have reported that invasive ductal carcinoma (IDC) with coexisting ductal carcinoma in situ (DCIS) show lower metastatic potential and recurrence and better overall survival than pure IDC. In this study, we assessed F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) imagesof patients with newly diagnosed IDC to...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016