Accurate detection of stent-graft migration in a pulsatile aortic model using Roentgen stereophotogrammetric analysis.

نویسندگان

  • Olivier H J Koning
  • Eric H Garling
  • Jan-Willem Hinnen
  • Lucia J M Kroft
  • Edwin van der Linden
  • Jaap F Hamming
  • Edward R Valstar
  • J Hajo van Bockel
چکیده

PURPOSE To evaluate the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for detecting stent-graft migration in an in vitro pulsatile circulation model and to study the feasibility of a nitinol endovascular clip (NEC) as an aortic wall reference marker for RSA. METHODS An aortic model with stent-graft was constructed and connected to an artificial circulation with a physiological flow and pressure profile. Tantalum markers and NECs were used as aortic reference markers for RSA analysis. Stent-graft migrations were measured during pulsatile circulation with RSA and CT. CT images acquired with 64 x 0.5-mm beam collimation were analyzed with Vitrea postprocessing software using a standard clinical protocol and central lumen line reconstruction. RSA in the model with the circulation switched off was used as the reference standard to determine stent-graft migration. The measurement errors of RSA and CT were determined during pulsatile circulation. RESULTS The mean measurement error +/- standard deviation (maximum) of RSA during pulsatile circulation using the tantalum markers was -0.5+/-0.16 (0.7) mm. Using the NEC, the mean (maximum) measurement error was -0.4+/-0.25 (1.1) mm. The mean (maximum) measurement error of CT was -1.1+/-1.17 (2.8) mm. CONCLUSION RSA is an accurate and feasible tool to measure stent-graft migration in a pulsatile environment. Migration measurement with RSA was more accurate than CT in this experimental setup. The nitinol clip tested in this study is potentially feasible as an aortic reference marker in patients after endovascular repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Roentgen stereophotogrammetric analysis: an accurate tool to assess stent-graft migration.

PURPOSE To evaluate in an in vitro model the feasibility and accuracy of Roentgen stereophotogrammetric analysis (RSA) versus computed tomography (CT) for the ability to detect stent-graft migration. METHODS An aortic model was constructed from a 22-mm-diameter Plexiglas tube with 6-mm polytetrafluoroethylene inlays to mimic the renal arteries. Six tantalum markers were placed in the wall of ...

متن کامل

Estimation of the migration of tibial components in total knee arthroplasty. A roentgen stereophotogrammetric analysis.

Accurate quantitative measurements of micromovement immediately after operation would be a reliable indicator of the stability of an individual component. We have therefore developed a system for measuring micromovement of the tibial component using three non-contact displacement transducers attached to the tibial cortex during total knee arthroplasty (TKA). Using this system we measured the in...

متن کامل

Biomechanical Analysis of Endovascular Abdominal Aortic Aneurysm Repair

Abstract. Longitudinal haemodynamic force (LF) acting on a bifurcated stent-graft has been estimated previously using a mathematical model which assumes steady flow of an invisid fluid. An experimental method was developed, using an instrumented stent-graft model, to measure LF under human physiological and pathological blood flow conditions. The physical stent-graft model, with main trunk diam...

متن کامل

Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA).

An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct either at the sites of fixation and/or between the sites of fixation (i.e., graft substance). Roentgen stereophotogrammetric analysis (RSA), which requires that radio-opaque markers be attached to the graft, has been shown to be a useful technique in...

متن کامل

Accuracy of EBRA-FCA in the measurement of migration of femoral components of total hip replacement. Einzel-Bild-Röntgen-Analyse-femoral component analysis.

Several methods of measuring the migration of the femoral component after total hip replacement have been described, but they use different reference lines, and have differing accuracies, some unproven. Statistical comparison of different studies is rarely possible. We report a study of the EBRA-FCA method (femoral component analysis using Einzel-Bild-Röntgen-Analyse) to determine its accuracy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2007