SSR Alleviation using BVLC Supplementary Controlled SVS of Series Compensated Power System
نویسندگان
چکیده
The sub synchronous resonance (SSR) is a substantial problem in power system having a steam turbine generator connected to a series compensated transmission system. Flexible AC transmission systems (FACTS) controllers are widely applied to mitigate SSR. In this paper, a bus voltage and line current (BVLC) supplementary subsynchronous damping controller (SSDC) is proposed to alleviate subsynchronous resonance (SSR) and damping power system oscillations in a power system. Both eigenvalue investigation and time-domain simulation results verify that the proposed method can damp torsional oscillations of the power system with SVS bus voltage and line current (BVLC) supplementary controller.The results demonstrate that the proposed controller has a successful performance in minimizing the SSR.It is shown that the controller is able to stabilize all unstable modes. The study is performed on the system adapted from the IEEE first benchmark model. All the simulations are carried out in MATLAB/SIMULINK environment.
منابع مشابه
Incorporation of SVS CBVLC Supplementary Controller for Damping SSR in Power System
Abstract—Static VAR System (SVS) is a kind of FACTS device which is used in power system primarily for the purpose of voltage and reactive power control. In this paper presents a systematic approach for designing SVS supplementary controller, which is used to improve the damping of power system oscillation. The combined bus voltage and line current (CBVLC) supplementary controller has been deve...
متن کاملMitigation of SSR Oscillations in Series Compensated Line using LCAP Subsynchronous Damping Controller
Subsynchronous Resonance (SSR) is a growing problem in power systems having series compensated transmission lines. Subsynchronous resonance with low frequency that surpasses aggregate fatigue threshold of the generator shaft frequently could significantly reduce the shaft service life, which is a new problem that emerges in recent years. Flexible AC transmission systems (FACTS) controllers are ...
متن کاملDynamic Stabilization of Wind Farms Deploying Static Synchronous Series Compensator
Encountering series-compensated transmission lines, sub-synchronous resonance (SSR) may strike the power system by jeopardizing its stability and mechanical facilities. This paper aims to verify the capability of static synchronous series compensator (SSSC) in mitigating the mechanical and electrical oscillations such as SSR in wind farm integrations. A wind turbine with a self–excited inductio...
متن کاملSupplementary Controller Design for SSR Damping in a Series-Compensated DFIG-Based Wind Farm
The increasing presence of wind power in power systems will likely drive the integration of large wind farms with electrical networks that are series-compensated to sustain large power flows. This may potentially lead to subsynchronous resonance (SSR) issues. In this paper, a supplementary controller on the grid-side converter (GSC) control loop is designed to mitigate SSR for wind power system...
متن کاملDamping analysis of sub-synchronous resonance (SSR) in a wind farm based on DFIG in a series compensated network
The effect of wind generator on sub-synchronous resonance (SSR) is being interested by increasing penetration of wind turbine in power systems,. Purpose of this article is to analyze SSR in a wind farm based on doubly fed induction generator (DFIG) which is connected to compensating series grid. A dynamic model for analysis of induction generator effect and Torsional Interaction (TI) has been u...