A U-HPLC-ESI-MS/MS-based stable isotope dilution method for the detection and quantitation of methotrexate in plasma.
نویسندگان
چکیده
INTRODUCTION High-dose methotrexate (MTX) is used in the treatment of proliferative diseases such as acute lymphoblastic leukemia. Therapeutic drug monitoring of plasma MTX is important to monitor efficacy and adverse events. The authors aimed to develop a liquid chromatography, electrospray ionization, tandem mass spectrometry (LC-ESI-MS/MS)-based method to determine MTX in plasma for therapeutic drug monitoring and pharmacokinetic studies. METHODS Samples were analyzed using a Waters Acquity UPLC and Quattro Premier XE. A Waters Acquity UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm) was used running an isocratic mobile phase of 21% methanol and 10 mM ammonium bicarbonate. The electrospray was operated in the positive ionization mode monitoring the following mass transitions: m/z 455.2 > 308.2 for MTX and m/z 458.2 > 311.2 for MTXd3. The analysis combined straightforward sample preparation, consisting of dilution and protein precipitation, with a 3-minute run time. RESULTS The method was linear up to 50 μM (r > 0.99), and the coefficient of variation was <6% for intraday and <10% for interday precision. Average recovery was 99%. There were no significant matrix effects. The lower limit of quantitation, defined as the lowest concentration at which the coefficient of variation <20% and S/N > 1:10, was 5 nM. Method comparison with the Abbott TDx fluorescent polarization immunoassay (FPIA) showed excellent agreement, and a small but significant negative constant bias was detected (LC-MS/MS = 0.98 × FPIA - 7.3). CONCLUSIONS [corrected] The authors developed a specific and sensitive stable isotope dilution LC-ESI-MS/MS method to monitor MTX concentrations in plasma within the clinically relevant range. The method can be easily applied in clinical laboratories because it combines straightforward sample pretreatment with LC-MS/MS.
منابع مشابه
Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma.
BACKGROUND It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet). METHODS We used stable-isotope dilution liquid chromatography-electrospr...
متن کاملIsotope dilution gas chromatographic-mass spectrometric measurement of tricyclic antidepressant drugs. Utility of the 4-carbethoxyhexafluorobutyryl derivatives of secondary amines.
Stable isotope dilution gas chromatographic-mass spectrometric (GC-MS) measurement of tricyclic antidepressants (TCA) is a useful alternative to high-performance liquid chromatography (HPLC) methods when interfering substances prevent accurate quantitation by HPLC. For satisfactory GC-MS analysis, secondary amine TCA must be derivatized. Commonly employed trifluoroacetyl and heptafluorobutyryl ...
متن کاملHigh-Performance Liquid Chromatography Determination of Methotrexate in Plasma
This article describes a simple and fast high-performance liquid chromatography method for the determination of methotrexate (MTX) in plasma. Samples were collocted from children receiving high-dose MTX at shafa Hospital (Ahvaz University of Medical sciences, Ahvaz, iran) at various times after the end of eachinfusion. Plasma was deproteinized with trichloroacetic acid and the supernatant was i...
متن کاملSystematic analysis of main constituents in rat biological samples after oral administration of the methanol extract of Fructus Aurantii by HPLC-ESI-MS/MS
High performance liquid chromatography (HPLC) with diode array detection (DAD) and electrospray ionization tandem mass spectrometry (ESI/MS/MS) was used to analyze the main components in the methanol extract of Fructus Aurantii (FA) and the metabolites in rat biological samples after oral administration of the methanol extract of FA. There were 31 constituents identified in the extract of FA in...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...