Reproducibility of the cold-induced vasodilation response in the human finger.

نویسنده

  • Catherine O'Brien
چکیده

Cold-induced vasodilation (CIVD) is a cyclic oscillation in blood flow that occurs in the extremities on cold exposure and that is likely associated with reduced risk of cold injury (e.g., frostbite) as well as improved manual dexterity and less pain while working in the cold. The CIVD response varies between individuals, but the within-subject reproducibility has not been adequately described. The purpose of this study was to quantify the within-subject variability in the CIVD response under standardized conditions. Twenty-one volunteers resting in a controlled environment (27 degrees C) immersed the middle finger in warm water (42 degrees C) for 15 min to standardize initial finger temperature and then in cold water (4 degrees C; CWI) for 30 min, on five separate occasions. Skin temperature (Tf) and blood flow (laser-Doppler; expressed as percent change from warm-water peak) responses that describe CIVD were identified, including initial nadir reached during CWI, onset time of CIVD, initial apex during CIVD, time of that apex, and overall mean during CWI. Within-subject coefficient of variation for Tf across the five tests for the nail bed and pad, respectively, were as follows: nadir, 9 and 21%; onset, 18 and 19%; apex, 12 and 17%; apex time, 23 and 24%; mean 10 and 15%. For blood flow, these values were as follows: nadir 52 and 64%; onset, 6 and 5%; apex, 33 and 31%; apex time 9 and 8%; and mean 43 and 34%. Greater variability was found in the temperature response of the finger pad than the nail bed, but for blood flow the variability was similar between locations. Variability in onset and apex time between sites was similar for both temperature and blood flow responses. The reproducibility of the time course of CIVD suggests this methodology may be of value for further studies examining the mechanism of the response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cold-induced vasodilatation response of finger skin blood vessels in older men observed by using a modified local cold tolerance test.

The time of onset and magnitude of cold-induced vasodilatation (CIVD) in six older men (62-70 years) were compared with those of seven younger men (20-29 years) by using a modified local cold tolerance test. This test consisted of a 10-min immersion of the left middle finger in cold water at 10 degrees C, and was substituted for a conventional test (30-min immersion in ice water at 0 degrees C)...

متن کامل

Finger cold-induced vasodilation: a review

Cold-induced vasodilation (CIVD) in the finger tips generally occurs 5–10 min after the start of local cold exposure of the extremities. This phenomenon is believed to reduce the risk of local cold injuries. However, CIVD is almost absent during hypothermia, when survival of the organism takes precedence over the survival of peripheral tissue. Subjects that are often exposed to local cold (e.g....

متن کامل

The Effect of Chronic Inflammation on Knee Joint Vascular β-adrenoceptors in Rabbit

It has been shown that inflammation reduces the effectiveness of sympathetic nerves in the regulation of knee joint blood flow, and the joint vascular- ß adrenoceptors are changed due to acute inflammation from a majority of ß-1 to an equality of ß-1 and ß-2 receptors.. To investigate the role of sympathetic nerves in nerve induced vasoconstriction and changes in joint vascular ß-adrenoceptors ...

متن کامل

Perfusion of the human finger during cold-induced vasodilatation.

We have investigated the effect of severe local cooling on the vasomotor activity of the arteriovenous anastomoses (AVAs) and other finger vessels. The right third finger was subjected to local cooling (3°C) for 30-45 min in 21 healthy, thermoneutral subjects. Blood velocity in the third finger arteries of both hands was simultaneously recorded using ultrasound Doppler, and skin temperature and...

متن کامل

Influence of thermal balance on cold-induced vasodilation.

We examined the effect of thermal balance perturbation on cold-induced vasodilation through a dynamic A-B-A-B design applying heat (condition A) and cold (condition B) to the body's core, while the hand is exposed to a stable cold stimulus. Fifteen healthy adults (8 men, 7 women) volunteered. Applications of heat and cold were achieved through water immersions in two tanks maintained at 42 and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 98 4  شماره 

صفحات  -

تاریخ انتشار 2005