Total ankle replacement using HINTEGRA, an unconstrained, three-component system: surgical technique and pitfalls.
نویسندگان
چکیده
Total ankle replacement (TAR) has become a valuable treatment option in patients with end-stage ankle osteoarthritis. One popular 3-component system, the HINTEGRA TAR, is an unconstrained system that provides inversion-eversion stability. More natural biomechanics of the replaced ankle may be expected when anatomic considerations drive prosthesis design. The HINTEGRA prosthesis includes 2 anatomically contoured metal components and a polyethylene insert, providing axial rotation and physiologic flexion-extension mobility. This article describes the HINTEGRA TAR design and surgical technique. Use of the prosthesis for complex hindfoot reconstruction in patients with an osteoarthritic, varus, or valgus ankle deformity is described.
منابع مشابه
Total Ankle Arthroplasty: Brazilian Experience with the Hintegra Prosthesis.
Ankle arthrosis is becoming more and more common. The search for solutions that preserve joint function has led to a new generation of prosthesis with three components and more degrees of freedom. This paper presents the results achieved for ten patients treated with the HINTEGRA Prosthesis (Integra, New Deal), through collaborative action between the Foot and Ankle Groups of the Orthopedics an...
متن کاملThe revolution and unanswered questions: commentary on an article by Beat Hintermann, MD, et al.: "HINTEGRA revision arthroplasty for failed total ankle prostheses".
BACKGROUND When a total ankle replacement fails, arthrodesis has been advocated as the treatment of choice. With the availability of a wide spectrum of implants, revision arthroplasty may become a viable alternative. METHODS We reviewed a consecutive series of 117 cases (116 patients [fifty-six female and sixty male]; mean age, 55.0 ± 12.0 years) in which a total ankle arthroplasty failed aft...
متن کاملThe International Documentation and Evaluation System IDES: a single center observational case series for development of an ankle prosthesis documentation questionnaire and study of its feasibility and face validity
BACKGROUND The number of implanted total ankle replacements is increasing and most articles present short- and mid-term results. Comparison of outcomes is difficult because of inconsistent terminology and different use of parameters. MATERIALS AND METHODS We created a module for total ankle prostheses in the framework of the International Documentation and Evaluation System (IDES). Content de...
متن کاملSurgical strategies: lateral ligament reconstruction as part of the management of varus ankle deformity with ankle replacement.
Improved designs and surgical technique has led to much better mid-term and longer term outcomes than the first generation ankle replacements of the 1970's. However, there remains multiple recent papers discussing the many potential complications with total ankle replacement surgery. As we proceed into the future, one should be cognizant of the pitfalls and know how to deal with the difficult a...
متن کاملRobotic cadaver testing of a new total ankle prosthesis model (GERMAN ANKLE SYSTEM)
BACKGROUND An investigation was carried out into possible increased forces, torques, and altered motions during load-bearing ankle motion after implantation of two different total ankle prostheses. We hypothesized that the parameters investigated would not differ in relation to the two implants compared. METHODS We included two different ankle prostheses (Hintegra, Newdeal, Vienne, France; Ge...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Foot and ankle clinics
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2012