Photogrammetry and 3D Scanning: Assessment of Metric Accuracy for the Digital Model of Danatello’s Maddalena*

نویسندگان

  • G. Tucci
  • G. Guidi
  • D. Ostuni
  • F. Costantino
  • M. Pieraccini
چکیده

The deployment of 3D optical scanning technologies for measuring three-dimensional shapes of sculptures of high morphological complexity, have seen recently a development so noticeable that it emerges as one of the most promising methods for the analysis and preservation of the Cultural Heritage. In spite of an undoubted richness of information produced with this technique, the method for generating a digital model from single 3D acquisitions involves errors propagation that may deteriorate the actual metric accuracy attainable with such procedure. The activity reported in this paper describes a recent experiment in 3D scanning of a highly complex sculpture: the wooden statue "Maddalena" by Donatello, kept in the museum of the “Opera del Duomo", in Florence. The acquisitions, taken with a commercial system based on fringe projection, give a local measurement uncertainty of about 70μm, but when the complete model is generated by automatic alignment of the raw 3D images in a common coordinate system, possible scale variations might be involved, especially along the height of the statue. With this preliminary work, the authors want to verify the metric reliability of the three-dimensional model, obtained through iterative alignments of single 3D acquisitions. For this purpose, a measurement over well-identified features of the sculpture have been performed and the distances between couples of significant points have been calculated with photogrammetric operations. By repeating the same measurements on the 3D model, a corresponding set of point-to-point distances have been evaluated and compared with the photogrammetric results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tridimensional digitizing of Donatello's Maddalena

3D optical scanning technologies for measuring tridimensional shapes of sculptures have emerged in the last few years as the most promising methods for digital analysis and preservation of Cultural Heritage. This paper presents the work leading to the generation of the digital 3D model of Donatello’s Maddalena, kept in the museum of the Opera del Duomo in Florence. The acquisitions have been ta...

متن کامل

Photogrammetry and Ground-based Laser Scanning: Assessment of Metric Accuracy of the 3D Model of Pozzoveggiani Church

Among the plenty of works so far presented on the use of laser scanning for cultural heritage survey, it can be noted that some geometric related issues have been not yet solved for. Most effort has been spent to achieve visually pleasant 3D models, mainly for VR applications, but only a few works addressed the metric and geometric accuracy of generated 3D models. According to such remark, in t...

متن کامل

Improvement of Metric Accuracy of Digital 3D Models through Digital Photogrammetry. A Case Study: Donatello's Maddalena

In spite of an undoubted richness of information produced by 3D optical technologies, in some cases, the method for generating a digital model from single 3D acquisitions involves the propagation of errors. These errors limit the overall metric accuracy attainable with such procedure. This happens when small 3D images are assembled together in order to model a large object. The authors present ...

متن کامل

Accuracy Verification and Enhancement in 3D Modeling: Application to Donatello's Maddalena

The three-dimensional acquisition and modeling of Donatello's Maddalena was started in order to create a methodology that aims at monitoring fragile wooden sculptures over the years. Hence a set of new approaches in 3D modeling was needed for obtaining the necessary metric reliability. The main focus of the work is modeling accuracy, therefore quality control procedures based both of the self c...

متن کامل

Improvement of metric accuracy of digital 3D models through digital photogrammetry. A case study: Donatello's Maddelena

In spite of an undoubted richness of information produced by 3D optical technologies, in some cases, the method for generating a digital model from single 3D acquisitions involves the propagation of errors. These errors limit the overall metric accuracy attainable with such procedure. This happens when small 3D images are assembled together in order to model a large object. The authors present ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001