Effect of different Ti-6Al-4V surface treatments on osteoblasts behaviour.

نویسندگان

  • Ching-Hsin Ku
  • Dominique P Pioletti
  • Martin Browne
  • Peter J Gregson
چکیده

The purpose of the present work was to examine the effect of different Ti-6Al-4V surface treatments on osteoblasts behaviour. Previous work in this laboratory has demonstrated that an ageing treatment reduces metal ion release from this alloy compared to standard passivation procedures. In this study. human osteosarcoma MG-63 were used in short-term in vitro tests to assay for cell viability and cell proliferation at 12, 24 and 72 h while SaOS-2 were used in long-term in vitro tests to assay for osteonectin, osteopontin, osteocalcin gene expression, total protein amount (TP). alkaline phosphatase activity (ALP) and fibronectin production (FN) for 1-4 weeks. Epifluorescence microscopy was used to observe SaOS-2 cell morphology. After 24h, there was no difference in MG-63 cell viability proliferation or in SaOS-2 cell morphology between the different surface treatments. For the long-term tests, the aged Ti-6Al4V induced significantly higher cell proliferation than the control Ti-6Al-4V at 72h. At week 1, no difference in the osteonectin, osteopontin, and osteocalcin gene expression was found between samples. The peak of ALP activity appeared earlier at week 2 for the control surface compared with the passivated and aged surfaces. The early increase in ALP activity for the control sample could be a compensatory effect of decreased osteoblasts proliferation. There was no difference in the expression of FN for the different surface treatments. Our present results showed that the different surface treatments, which induced different metal ion release kinetics and surface properties, influenced the cell proliferation and ALP activity of osteoblast cells. Aluminium ions release kinetics as well as presence of vanadium ions may play a major role in influencing the osteoblasts behaviour in the present study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical Surface Treatments of Ti-6Al-4V Miniplate Implant Manufactured by Electrical Discharge Machining (TECHNICAL NOTE)

Present work aims at multi-mechanical surface treatment of Ti-6Al-4V based-miniplate implant manufactured by electrical discharge machining (EDM) for biomedical use. Mechanical surface treatment consists of consequent use of ultrasonic cleaning, rotary tumbler polishing, and brushing. Surface layers are analyzed employing scanning electron microscopy and energy dispersive X-ray spectroscopy. Al...

متن کامل

Large-scale gene expression analysis of osteoblasts cultured on three different Ti-6Al-4V surface treatments.

To improve implant biocompatibility, we developed a simple cost-effective thermal surface treatment allowing an increase in the oxide layer thickness of a titanium (Ti) alloy used in orthopaedic implants. The goal of this study was to test in vitro the reaction of osteoblasts to the developed surface treatment and to compare it to the osteoblast reaction to two other surface treatments currentl...

متن کامل

Vickers hardness of cast commercially pure titanium and Ti-6Al-4V alloy submitted to heat treatments.

The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat trea...

متن کامل

Selective Laser Melting Produced Ti-6Al-4V: Post-Process Heat Treatments to Achieve Superior Tensile Properties

Current post-process heat treatments applied to selective laser melting produced Ti-6Al-4V do not achieve the same microstructure and therefore superior tensile behaviour of thermomechanical processed wrought Ti-6Al-4V. Due to the growing demand for selective laser melting produced parts in industry, research and development towards improved mechanical properties is ongoing. This study is aimed...

متن کامل

Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

PURPOSE The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS AND METHODS The zirconium films were developed on Ti-6Al-4V discs using RF magnetron sputtering method. Surface profile, surface composition, surface roughness and surface energy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomaterials

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2002