Nasal versus oral intubation for mechanical ventilation of newborn infants.

نویسندگان

  • K Spence
  • P Barr
چکیده

BACKGROUND This section is under preparation and will be included in the next issue. OBJECTIVES The purpose of the review was to compare the complications associated with intubation by the nasal route with those associated with intubation by the oral route for mechanical ventilation in newborn infants. SEARCH STRATEGY The standard search strategy of the Neonatal Review Group as outlined in the Cochrane Library was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Register of Controlled Trials, MEDLINE and CINAHL. A call was placed on the list servers, NICU-NET and Neonatal Talk for unpublished trials, conference presentations and current trials. SELECTION CRITERIA All trials using random or quasi-random allocation of patients to either the nasal or oral route of intubation were included. Study quality and eligibility were assessed independently by each author. DATA COLLECTION AND ANALYSIS The standard method of the Cochrane Collaboration and the Neonatal Review Group was used to assess the methodological quality of the included studies. The methodological quality of each study was reviewed by the second author blinded to study authors and institutions. Each reviewer extracted data separately before comparison and resolution of differences. The standard method of the Neonatal Review Group was used to measure the effect of the different routes of intubation, using Relative Risk (RR) and 95% Confidence Intervals (CI). MAIN RESULTS Only two eligible randomized trials were found. Data from these two trials failed to show significant differences between the oral and nasal route of intubation for mechanically ventilated neonates. The rate of failure to intubate using the nasal route was higher in one study. One study found post extubation atelectasis occurred more frequently in nasally intubated infants who weighed less than 1500 grams. The rates of malposition of the tube at the initial intubation, accidental extubation, tube blockage, re-intubation after extubation, septicaemia, clinical infection and local trauma (nasal erosion or palatal groove) were not significantly different for the two groups. REVIEWER'S CONCLUSIONS Post extubation atelectasis may be more frequent after nasal intubation, particularly in very low birth weight infants. One route of intubation does not seem to be preferable to the other. There is a need for further randomized controlled trials containing larger numbers of infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

Commentary: concerns for complementary feeding of infants in Brazil.

1. Philip AG. The evolution of neonatology. Pediatr Res. 2005;58:799-815. 2. Carvalho FL, Mezzacappa MA, Calil R, Machado HC. Incidence and risk factors of accidental extubation in a neonatal intensive care unit. J Pediatr (Rio J). 2010;86:189-95. 3. Brown MS. Prevention of accidental extubation in newborns. Am J Dis Child. 1988;142:1240-3. 4. Little LA, Koenig JC Jr, Newth CJ. Factors affectin...

متن کامل

A Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome

Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....

متن کامل

Nasal continuous positive airway pressure (CPAP) for the respiratory care of the newborn infant.

Nasal continuous positive airway pressure (CPAP) is a noninvasive form of respiratory assistance that has been used to support spontaneously breathing infants with lung disease for nearly 40 years. Following reports that mechanical ventilation contributes to pulmonary growth arrest and the development of chronic lung disease, there is a renewed interest in using CPAP as the prevailing method fo...

متن کامل

A Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome

Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Cochrane database of systematic reviews

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2000