Simultaneous Determination of Cadmium and Lead Using PEDOT/PSS Modified Glassy Carbon Electrode

نویسندگان

  • Sukeri Anandhakumar
  • Jayaraman Mathiyarasu
  • Kanala Lakshmi
  • Narasimha Phani
  • Venkataraman Yegnaraman
چکیده

In this work, we report the simultaneous determination of cadmium and lead using glassy carbon electrodes (GCE) modified by poly(3,4-ethylenedioxythiophene) (PEDOT) for linear sweep anodic stripping voltammetry (LSASV). The modification allows metal detection without involving oxygen removal, mechanical stirring and introduction of alloying additions such as Hg, Bi, Sb, etc. during the pre-concentration step. Introduction of poly (4-styrenesulphonate) (PSS) as dopant in the PEDOT matrix improves reproducibility, stability and sensitivity in the detection. Both cadmium and lead peaks were readily quantifiable over the linear range of 2 10 g/ml and the detection limit being 1.47 g/ml and 1.15 g/ml respectively. The calibration plot shows a linear response with correlation coefficient of 0.9911 and 0.9944 for cadmium and lead respectively. Thus, the GC/PEDOT/PSS modified electrode suggested as a suitable matrix for rapid monitoring of these heavy metals at trace levels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex

A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...

متن کامل

Simultaneous electrochemical determination of Acetaminophen and Codeine based on a MWCNT/MCM48 nanocomposite modified glassy carbon

A novel chemically modified electrode was constructed based on multi-walled carbon nanotubes, MCM48 molecular sieve composite modified glassy carbon electrode .The modified electrode showed that it can be used for simultaneous determination of acetaminophen (ACT) and codeine (COD), simultaneously. The measurements were carried out by the application of differential pulse voltammetry (DPV), cycl...

متن کامل

A Sensitive Simultaneous Determination of Uric Acid, Norepinephrine and Indomethacin using a Cadmium Sulfide Nanoparticles/Multi-Walled Carbon Nanotubes Modified Gold Electrode

In this study a novel method was developed to fabricate cadmium sulfide nanoparticles/multiwalled carbon nanotubes composite modified gold electrode (CdSNPs/MWCNTS/AuE) to measure trace amounts of norepinephrine(NE), indomethacin (IND), and uric acid (UA) simultaneously. Electrochemical investigations were carried out using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chron...

متن کامل

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

متن کامل

Application of CuO nano particle/multi-walled carbon nanotube nanocomposite modified electrode for simultaneous determination of dopamine and rutin in real samples

Background: In this work, a new method was developed for simultaneous determination of dopamine and rutin at glassy carbon electrode modified with CuO nanoparticles doped multi-walled carbon nanotubes (CuONPs–MWNT/GCE). This modified electrode has shown excellent electrocatalytic activity toward the oxidation of rutin in acetate buffer solution (pH=5). The modified electrode lowered the overpot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011