Graphical methods for quantifying macromolecules through bright field imaging

نویسندگان

  • Hang Chang
  • Rosa Anna DeFilippis
  • Thea D. Tlsty
  • Bahram Parvin
چکیده

Bright field imaging of biological samples stained with antibodies and/or special stains provides a rapid protocol for visualizing various macromolecules. However, this method of sample staining and imaging is rarely employed for direct quantitative analysis due to variations in sample fixations, ambiguities introduced by color composition and the limited dynamic range of imaging instruments. We demonstrate that, through the decomposition of color signals, staining can be scored on a cell-by-cell basis. We have applied our method to fibroblasts grown from histologically normal breast tissue biopsies obtained from two distinct populations. Initially, nuclear regions are segmented through conversion of color images into gray scale, and detection of dark elliptic features. Subsequently, the strength of staining is quantified by a color decomposition model that is optimized by a graph cut algorithm. In rare cases where nuclear signal is significantly altered as a result of sample preparation, nuclear segmentation can be validated and corrected. Finally, segmented stained patterns are associated with each nuclear region following region-based tessellation. Compared to classical non-negative matrix factorization, proposed method: (i) improves color decomposition, (ii) has a better noise immunity, (iii) is more invariant to initial conditions and (iv) has a superior computing performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Imaging of Cryo-Bright Field, Dark Field STEM and SEM Using Unroofed Living Cells with Special Reference to Membrane Cytoskeletons

Cryo-electron microscopy has been used exclusively so far for single particle analysis or crystallography of purified proteins. Recently, technical improvements on rapid freezing and cryo-microtome permitted structural analysis of organelle or macromolecules in native state using whole cells (1,2) and vitreous cryo-sections (3). However, cryo-sections don’t scatter electrons so much and therefo...

متن کامل

Reduction of the Magic Angle Effect on Contrast in Magnetization Transfer Imaging of Human Cartilage

INTRODUCTION In this study of human cartilage, we tested the hypothesis that the magic angle effect is reduced more in MT-weighted images than in T2-weighted images. Articular cartilage has three structural zones distinguished by collagen fiber orientations: superficial zone, transitional zone, and radial zone. When collagen fibers are oriented at 54.7°with respect to the main magnetic field of...

متن کامل

Imaging moving targets through scattering media.

Optical microscopy in complex, inhomogeneous media is challenging due to the presence of multiply scattered light that limits the depths at which diffraction-limited resolution can be achieved. One way to circumvent the degradation in resolution is to use speckle- correlation-based imaging (SCI) techniques, which permit imaging of objects inside scattering media at diffraction-limited resolutio...

متن کامل

Graphical analysis of grain yield stability for selection of suprior barley (Hordeum vulgare L.) promising lines in temperate regions of Iran

Quantifying genotype × environment interaction effect and yield stability under different environmental conditions is very important challenge in plant breeding programs. The aim of this study was to quantify genotype × environment interaction effect on grain yield and grain yield stability of barley promising lines in temperate regions of Iran. Nineteen promising barley lines (G1-G19) along wi...

متن کامل

Maximum Efficiency STEM Phase Contrast Imaging

Various bright-field (BF) imaging modes are available in scanning transmission electron microscopy (STEM). The mode equivalent to phase contrast imaging in conventional high-resolution transmission electron microscopy (TEM) involves a detector about an order of magnitude smaller than the convergence angle of the probe. This means a large proportion of the incident electrons go to waste as most ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bioinformatics

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2009