Quantitative 99mTc-Sestamibi Defect Size
نویسندگان
چکیده
Background. Serial myocardial perfusion imaging with "'Tc-sestamibi (MIBI) was used to evaluate infarct risk area and salvage after thrombolysis. The purpose of this investigation was to determine whether changes in MIBI defect size observed after reperfusion may result in part from distortion of regional and global left ventricular geometry. Methods and Results. Twenty-five open-chest dogs were subjected to either 15 minutes (groups 1A and 1B) or 3 hours (group 2) of left anterior descending coronary artery occlusion followed by 3 hours of reperfusion. MIBI was injected before occlusion (group 1A) or during occlusion (groups 1B and 2), and serial ECG-gated planar imaging was performed. Dobutamine was infused after 3 hours of reperfusion (groups 1B and 2) to transiently alter left ventricular size and function. Perfusion defect magnitude (DM) and extent (DE) were serially quantified with circumferential profile analysis of end-systolic (ES), end-diastolic (ED), and summed images. Flow was assessed with radiolabeled microspheres and correlated with myocardial MIBI activity. Myocardial thickening was assessed in the risk area with sonomicrometers. In group lA dogs, ischemic dyskinesis produced large artifactual quantitative MIBI defects on ES images (DM, 9.3±13; DE, 27.8±6.0) that were significantly smaller on ED images (DM, 4.5±0.9, P<.05; DE, 4.4±2.3, P<.05). In addition, DM and DE correlated inversely with myocardial thickening on ES images (DM, r= -.84; DE, r= -.78) and summed images (DM, r= -.72; DE, r= -.61) but not ED images (DM, r= -.12; DE, r= -.15). An index of defect reduction derived from summed images correlated well with thickening fraction in stunned dogs (group 1B, r=.89) but poorly in infarcted dogs (group 2, r=.41) subjected to dobutamine stress. Conclusions. "Tc-MIBI defect size may be affected by alteration of left ventricular geometry. Changes in regional function may confound analysis of risk area and myocardial salvage with serial ""Tc-MIBI imaging and may also affect defect size during pharmacological stress with dobutamine. Dobutamine 99mTc-MIBI imaging may be useful for distinguishing viable and nonviable myocardium. (Circulation. 1993;88[part 11:2224-2234.)
منابع مشابه
Enhanced regional washout of technetium-99m-sestamibi in patients with coronary spastic angina.
BACKGROUND Reverse redistribution and rapid washout of 99mTc-sestamibi are observed in patients with acute myocardial infarction and may indicate viable myocardium. However, the clinical significance of this phenomenon has not been rigorously examined in other cardiac diseases. Thus, we investigated whether reverse redistribution and washout of 99mTc-sestamibi could be used in the diagnosis and...
متن کاملDetermination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging
Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...
متن کاملComparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer
BACKGROUND Molecular breast imaging (MBI) performed with 99mTc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99mTc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99mTc sestamibi and 99mTc maraciclatide in patients with suspected breast cancer, u...
متن کاملVisual evaluation and differentiation of renal oncocytomas from renal cell carcinomas by means of 99mTc-sestamibi SPECT/CT
BACKGROUND Despite the progress in the quality of multiphasic CT and MRI scans, it is still difficult to fully characterize a solid kidney lesion. Approximately 10% of all solid renal tumours turn out to be oncocytomas. In actual clinical practice, this is verified only following unnecessary surgery or a renal biopsy/ablation. The objective of our pilot study examines whether 99mTc-sestamibi SP...
متن کاملA new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility.
UNLABELLED We have developed a new, completely automatic 3-dimensional software approach to quantitative perfusion SPECT. The main features of the software are myocardial sampling based on an ellipsoid model; use of the entire count profile between the endocardial and epicardial surfaces; independence of the algorithm from myocardial shape, size, and orientation and establishment of a standard ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005