Acute respiratory failure due to hemothorax after posterior correction surgery for adolescent idiopathic scoliosis: a case report

نویسندگان

  • Yoji Ogura
  • Kota Watanabe
  • Naobumi Hosogane
  • Yoshiaki Toyama
  • Morio Matsumoto
چکیده

BACKGROUND Although posterior correction and fusion surgery using pedicle screws carries the risk of vascular injury, a massive postoperative hemothorax in a patient with adolescent idiopathic scoliosis (AIS) is quite rare. We here report a case of a 12-year-old girl with AIS who developed a massive postoperative hemothorax. CASE PRESENTATION The patient had a double thoracic curve with Cobb angles of 63° at T2-7 and 54° at T7-12. Posterior correction and fusion surgery was performed using a segmental pedicle screw construct placed between T2 and T12. Although the patient's respiration was stable during the surgery, 20 minutes after removing the trachea tube, the patient's pulse oximetry oxygen saturation suddenly decreased to 80%. A contrast CT scan showed a massive left hemothorax, and a drainage tube was quickly inserted into the chest. The patient was re-intubated and a positive end-expiratory pressure of 5 cmH(2)O applied, which successfully stopped the bleeding. The patient was extubated 4 days after surgery without incident. Based on contrast CT scans, it was suspected that the hemothorax was caused by damage to the intercostal arteries or branches during pedicle probing on the concave side of the upper thoracic curve. Extensive post-surgical blood tests, echograms, and CT and MRI radiographs did not detect coagulopathy, pulmonary or vascular malformation, or any other possible causative factors. CONCLUSION This case underscores the potential risk of massive hemothorax related to thoracic pedicle screw placement, and illustrates that for this serious complication, respiratory management with positive airway pressure, along with a chest drainage tube, can be an effective treatment option.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Massive hemothorax caused by Gelpi retractor during posterior correction surgery for adolescent idiopathic scoliosis: a case report

BACKGROUND CONTEXT Gelpi retractors are used in surgery because they can reduce paravertebral muscle damage during retraction. No pleural injuries associated with their use in posterior spine surgery have been reported. PURPOSE To describe a patient who suffered a massive postoperative hemothorax caused by a Gelpi retractor used during posterior correction surgery for adolescent idiopathic sc...

متن کامل

Massive Hemothorax after Posterior Correction Surgery of Adolescent Idiopathic Scoliosis: A Case Report

Posterior spine correction and fusion for AIS is considered a safe procedure and is currently the gold-standard in the treatment of progressive curves. Nevertheless, both neurologic and nonneurologic complications may occur [1,2]. Lung complications are rare, being reported in 0.9% of cases. In this sense, hemothorax complications occur in only 0.1% of surgical procedures [3-5]. Hemothorax typi...

متن کامل

عملکرد ریوی در اسکولیوز ایدیوپاتیک نوجوانان قبل از جراحی ستون فقرات و تاثیر نوع جراحی بر آن

Background: Scoliosis is one of the most common spinal deformities with subsequent decrease in pulmonary function. The effects of surgical correction on the pulmonary function of patients with adolescent idiopathic scoliosis are controversial. The purpose of the present study was to compare the postoperative pulmonary function changes in different surgical approaches chosen for its correction. ...

متن کامل

Patient satisfaction after scoliosis surgery

 Abstract Background: Patient satisfaction with the cosmetic result of spinal fusion surgery was studied in 40 cases of adolescent idiopathic scoliosis. Neutral or dissatisfied patients were compared with satisfied patients in several physical and psychological characteristics. The aim of the study was to determine whether adolescents generally report satisfaction with the postoperative appeara...

متن کامل

Reinstrumentation for rapid curve progression after implant removal following posterior instrumented fusion in adolescent idiopathic scoliosis: a case report

BACKGROUND CONTEXT Spinal implants are occasionally removed due to infection or soft tissue irritation secondary to prominence. Several studies have reported loss of scoliotic curve correction after implant removal. However, further review of the literature reveals no similar cases of rapid curve progression following implant removal in patients with adolescent idiopathic scoliosis (AIS) necess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013