Standardized LC-MS/MS based steroid hormone profile-analysis.
نویسندگان
چکیده
In order to overcome many limitations of immunoassays, high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has the potential to find its place in the clinical laboratory medicine for quantification of steroid hormones. A prerequisite for the application of a new analytical procedure in clinical diagnostics is standardization to minimize analytical intra- and interlaboratory variability and inaccuracy. We evaluate a newly standardized HPLC-MS/MS assay in kit-format, developed for routine determination of 16 steroid hormones in human serum samples. Fifteen metabolites can be measured quantitatively, which include aldosterone, androstenedione, androsterone, corticosterone, cortisol, cortisone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), dehydroepiandrosterone sulfate (DHEAS), 17β-estradiol (E2), estrone (E1), etiocholanolone, 17α-hydroxyprogesterone (17OHP), progesterone, and testosterone. 11-Deoxycorticosterone is the only compound rated as semi-quantitative in this kit. The sample preparation is performed by solid phase extraction (SPE) on a 96-well plate. The standardized assay has been validated for human serum in terms of lower and upper limit of quantification (LLOQ 0.01-32 ng/mL, ULOQ 5-8000 ng/mL), linear correlation coefficient of calibration (R(2)>0.9966), intra- and inter-day precision (intra-day 1.1-8.8%, inter-day 5.2-14.8% and 8.2-18.6% for 11-deoxycorticosterone), accuracy (intra-day 88.3-115.5% and 109.3-128.2% for 11-deoxycorticosterone, inter-day 91.4-117.2% and 102.3-137.1% for 11-deoxycorticosterone), analytical total error (3.6-17.8%), proficiency test accuracy (85.4-113.4%), recovery (68-99%), and metabolite stability (freeze/thaw stability 95.5-108.1%, short term stability 86.9-107.2%). Inter-assay comparison with a routine reference HPLC-MS/MS assay and seven immunoassays demonstrates the outstanding high performance of this HPLC-MS/MS based kit by improvements in accuracy for progesterone, androstenedione, and 17OHP. Finally, results of two metyrapone tests demonstrate the potential of the standardized HPLC-MS/MS assay for the analysis of a comprehensive steroid hormone profile in clinical diagnostics.
منابع مشابه
Gas chromatography/mass spectrometry (GC/MS) remains a pre-eminent discovery tool in clinical steroid investigations even in the era of fast liquid chromatography tandem mass spectrometry (LC/MS/MS)☆
Liquid chromatography tandem mass spectrometry (LC/MS/MS) is replacing classical methods for steroid hormone analysis. It requires small sample volumes and has given rise to improved specificity and short analysis times. Its growth has been fueled by criticism of the validity of steroid analysis by older techniques, testosterone measurements being a prime example. While this approach is the gol...
متن کاملLC-MS as a method for non-invasive measurement of steroid hormones and their metabolites in urine and faeces of animals
This review presents the technique of liquid chromatography-mass spectrometry (LC-MS). It brie y outlines how LC-MS works, its different functions, the different types of instruments available, the applications with which it is mainly used and the costs involved. In particular, it highlights the effectiveness of LC-MS in measuring steroids and emphasizes its usefulness in measuring steroids non...
متن کاملSteroid hormone analysis by tandem mass spectrometry.
BACKGROUND New high-performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) methods are among the most successful approaches to improve specificity problems inherent in many immunoassays. CONTENT We emphasize problems with immunoassays for the measurement of steroids and review the emerging role of LC-MS/MS in the measurement of clinically relevant steroids. The latest generatio...
متن کاملReproducibility of serum sex steroid assays in men by RIA and mass spectrometry.
There is an increasing trend to apply gas chromatography combined with mass spectrometry (GC-MS) or liquid chromatography tandem mass spectrometry (LC-MS/MS) assay methods to large-scale epidemiologic studies for the measurement of serum sex steroids. These methods are generally considered the gold standard for sex steroid measurements because of their accuracy, sensitivity, turnaround time, an...
متن کاملSteroid measurement with LC-MS/MS in pediatric endocrinology.
The liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an increasingly common tool in the clinical laboratory. Established applications include routine assays for detecting inborn errors of metabolism and for monitoring therapeutic drugs and steroids. Steroid profiling is a very effective method for distinguishing almost all steroid related disorders. It allows accurate diagnosis and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of steroid biochemistry and molecular biology
دوره 129 3-5 شماره
صفحات -
تاریخ انتشار 2012