Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery.

نویسندگان

  • P-G Guinot
  • B de Broca
  • O Abou Arab
  • M Diouf
  • L Badoux
  • E Bernard
  • E Lorne
  • H Dupont
چکیده

BACKGROUND The objective of this study was to test whether non-invasive assessment of respiratory stroke volume variation (ΔrespSV) by oesophageal Doppler monitoring (ODM) can predict fluid responsiveness during surgery in a mixed population. The predictive value of ΔrespSV was evaluated using a grey zone approach. METHODS Ninety patients monitored using ODM who required i.v. fluids to expand their circulating volume during surgery under general anaesthesia were studied. Patients with a preoperative arrhythmia, right ventricular failure, frequent ectopic beats, or breathing spontaneously were excluded. Haemodynamic variables and oesophageal Doppler indices [peak velocity (PV), stroke volume (SV), corrected flow time (FTc), cardiac output (CO), ΔrespSV, and respiratory variation of PV (ΔrespPV)] were measured before and after fluid expansion. Responders were defined by a >15% increase in SV after infusion of 500 ml crystalloid solution. RESULTS SV was increased by ≥15% after 500 ml crystalloid infusion in 53 (59%) of the 90 patients. ΔrespSV predicted fluid responsiveness with an area under the receiver-operating characteristic (AUC) curve of 0.91 [95% confidence interval (95% CI): 0.85-0.97, P<0.0001]. The optimal ΔrespSV cut-off was 14.4% (95% CI: 14.3-14.5%). The grey zone approach identified 12 patients (14%) with a range of ΔrespSV values between 14% and 15%. FTc was not predictive of fluid responsiveness (AUC 0.49, 95% CI: 0.37-0.62, P=0.84). CONCLUSIONS ΔrespSV predicted fluid responsiveness accurately during surgery over a ΔrespSV range between 14% and 15%. In contrast, FTc did not predict fluid responsiveness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of stroke volume variation obtained by arterial pulse contour analysis to predict fluid responsiveness intraoperatively.

BACKGROUND Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fl...

متن کامل

Respiratory stroke volume variation assessed by oesophageal Doppler monitoring predicts fluid responsiveness during laparoscopy.

BACKGROUND This study was designed to assess the ability of the stroke volume respiratory variation (ΔrespSV) determined by oesophageal Doppler monitoring (ODM) to predict the response to volume expansion (VE) during pneumoperitoneum. The predictive value of ΔrespSV was evaluated according to the concept of the 'grey zone'. METHODS Patients operated on laparoscopy and monitored by ODM were pr...

متن کامل

Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery.

BACKGROUND Off-line calculation of the pulse pressure variation (PPV(ref)) has repeatedly been shown to be a reliable predictor of fluid responsiveness in mechanically ventilated patients. This study was designed to assess the ability of two algorithms for automated calculation of PPV (PPV(auto)) (Intellivue MP 70) and stroke volume variation (SVV(auto)) (FloTrac/Vigileo) to predict fluid respo...

متن کامل

Prediction of fluid responsiveness using a non-invasive cardiac output monitor in children undergoing cardiac surgery.

BACKGROUND This study evaluated the ability of a non-invasive cardiac output monitoring device (NICOM) to predict fluid responsiveness in paediatric patients undergoing cardiac surgery. METHODS Children aged <5 yr undergoing congenital heart surgery were included. Once the sternum had been closed after repair of the congenital heart defect, 10 ml kg(-1) colloid solution was administered for v...

متن کامل

Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness.

BACKGROUND Corrected flow time (FTc) by oesophageal Doppler is considered to be a 'static' preload index. We evaluated the ability of FTc to predict fluid responsiveness and compared this with the abilities of other preload indices, such as pulse pressure variation (PPV), central venous pressure (CVP), and left ventricular end-diastolic area index (LVEDAI). METHODS Twenty neurosurgical patien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 110 1  شماره 

صفحات  -

تاریخ انتشار 2013