Bioabsorbable osteofixation devices in craniosynostosis. Clinical experience in 216 cases.
نویسندگان
چکیده
INTRODUCTION The pursuit of bone fixation systems capable of affording appropriate stability for osteosynthesis has gone through several stages from the use of metal wires, plates, and screws to the current stage of bioabsorbable systems. In our Pediatric Neurosurgery Service and Craniofacial Surgery Unit we began employing these systems in June 1997. The object of this paper is to present a review of the bioabsorbable materials most commonly used in pediatric age, and more specifically in treating craniosynostosis, to describe the characteristics of each one of them and our experience. PATIENTS AND METHODS From June 1997 to May 2006 we implanted bioabsorbable fixation systems in 216 patients diagnosed with craniosynostosis. Age at treatment ranged between 4 and 24 months (mean age 6.38 months). Brain computed tomography (CT) scans, and three-dimensional (3-D) reconstruction of CT scans were performed before and after treatment. An 82: 18 L-lactic acid: glycolic acid copolymer was used in 92.2% of these cases, and a 70:30 L-lactic acid: D-lactic acid copolymer was used in the remaining 7.8% of cases. The follow-up of the patients ranged between six months and five years. RESULTS There was no displacement of bioabsorbable plates or screws in any case. In one case (0.46%), radiological imaging revealed osteolysis underneath the implant eight months after the surgical procedure. Prominences caused by the plates and screws employed were visible in two cases (0.93%). We found fractures in the osteosynthesis mesh in two patients (0.93%). Four patients (1.85%) presented local inflammation. No alterations of cranial morphology secondary to inadequate stability were observed. CONCLUSIONS 1) Bioabsorbable fixation systems provide excellent stability during the bone "healing" period, without a higher complication rate than with other systems. 2) They help the bone grafts keep their remodeled shape. 3) They promote reossification by preventing the bone grafts from moving after osteosynthesis. 4) No interference with normal growth of the cranial vault has been observed.
منابع مشابه
Bioabsorbable osteofixation for orthognathic surgery
Orthognathic surgery requires stable fixation for uneventful healing of osteotomized bony segments and optimal remodeling. Titanium plates and screws have been accepted as the gold standard for rigid fixation in orthognathic surgery. Although titanium osteofixation is the most widely used approach, the use of bioabsorbable devices has been increasing recently. Biodegradation of bioabsorbable de...
متن کاملSelf-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.
Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided ...
متن کاملThe Effect of Inhalation Anesthesia with Hyperventilation and Total Intravenous Anesthesia on Intracranial Pressure Control in Pediatrics with Craniosynostosis Surgery: A Randomized Clinical Trial
Background: Intracranial pressure (ICP) control is one of the anesthesiologist challenges in craniosynostosis repair surgery, especially in multiple sutures involvement. The aim of this study was comparing the effect of two anesthesia methods including inhalation with hyperventilation and total intravenous anesthesia (TIVA) on ICP control and surgeon satisfaction in pediatrics with craniosynost...
متن کاملReliability of Visually Estimated Blood Loss with Hemoglobin Measurement: 200 Cases of Craniosynostosis Surgery
Background Bleeding is one of the most common complications of craniosynostosis surgery, which its appropriate management is associated with better post-operative outcomes. The aim of this retrospective study was to evaluate the visual estimated blood loss in intraoperative management of infants with craniosynostosis surgery. Materials and Methods This retrospective study was performed on 200 p...
متن کاملEfficacy and safety of biodegradable osteofixation devices in oral and maxillofacial surgery: a systematic review.
The use of osteofixation devices should be evidence-based if uncomplicated bone healing is to be achieved. Numerous studies describe and claim the advantages of biodegradable over titanium devices as a bone fixation method. Here, we systematically review the available literature to determine the clinical efficacy and safety of biodegradable devices compared with titanium devices in oral and max...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurocirugia
دوره 20 3 شماره
صفحات -
تاریخ انتشار 2009